MLC 104 IP Plus Series • Software-based Configuration and Control
46
A brief guide to Global Configurator tabs
In the upper right side of the GC window are several tabs that divide the program into
groups of functions you can view and configure. The left three,
IP Link Settings
,
Schedule
, and
Monitor
, are displayed for all IP Link-enabled products. Tabs to the right
of those three vary in quantity, type, and layout, depending on the product being configured.
The figure below shows tabs that may be available when you configure an MLC 104 IP Plus.
To learn about the functions available on each of these tabs, see the
Global Configurator
Help
file. In the contents pane on the left, click on
Reference Information
, click
Global Configurator Window
, then click on the name of the tab you want to know
more about.
Advanced Configuration
IR Learning to Create Customized IR Driver Files
If you do not find a driver on the Extron website for the device you plan to use, you can
create your own IR driver file. Extron IR Learner
™
software lets you create a customized
driver file of IR commands that can be used with the Global Configurator software for port
setup and button configuration. Visit
to download IR Learner and
install it on your PC.
Once IR Learner is installed on the PC, you can start the program directly
by double-clicking the IR Learner icon, shown at right.
Or, you can select
Run IR Learner
from the Global Configurator
Tools
menu,
as shown at right. The IR Learner utility opens in a
new window.
See the
IR Learner Help
file for instructions on
how to create the driver file. During IR command
capture, hold the remote control for the projector
or other device so it is facing the IR learning receiver on the MLC within the angles and
distance range shown in the figure on page
.
NOTE:
The MLC 104 IP Plus requires IR Learner version 1.23 or higher.
Advanced Configuration Options in Global Configurator
In Global Configurator in the
Advanced Configuration
tab you can set
•
What happens during power-up and power-down cycles and for how long
•
Personal identification numbers (PINs) and whether or not each PIN is enabled during
(executive mode) (see page 14 for details)
•
Volume adjustment parameters
•
Configuration for each digital port
•
Miscellaneous settings including whether to reset button statistics or upload the
enhanced web pages when the configuration is uploaded to the MLC
The
Global Configurator Help
file explains these features in the reference section about
the
Advanced Configuration
tab and in the MLC-specific instructions for configuring
Summary of Contents for MLC 104 IP Plus Series