MLC 104 IP Plus Series • Firmware Updates
158
6.
In the
Choose File to Upload
dialog box, locate and select the firmware file (*.
s19
)
you downloaded to
C:\Program Files (x86)\Extron\Firmware\MLC_104_
IP_PLUS\
xx
, and click the
Open
button.
7.
Click
Upload
button on the web page to upload the firmware to the controller. It takes a
while to load the file into the controller. You do not see any on-screen indication when
the upload has finished. Once the firmware upload is completed, the MLC performs a
reset.
8.
starting on page 31 in the “Installation”
section and see the
Global Configurator Help
file for instructions on how to restore a
configuration.
Updating Firmware Via Extron Firmware Loader Software
This method allows you to update one MLC at a time via IP or RS 232 communication using
Firmware Loader software (available free from
).
NOTE:
The MLC 104 IP Plus requires Firmware Loader version 4.0 or higher.
1.
If not already installed, download Firmware Loader from the Extron website and follow
the on-screen instructions to install it.
2.
Download the
.s19
firmware file to the PC.
3.
Start the Firmware Loader (FWLoader,
) software on the connected PC. The
Add
Device
dialog box opens.
4.
In the
Add Device
dialog box, choose the type of device (MLC 104 IP Plus).
5.
Select the communication type (connection method) and settings.
•
For
IP communication
, select
TCP/I
, enter the IP address of the controller,
verify or change the Telnet port number, and enter an administrator password if a
password has been set for the unit.
NOTE:
Passwords must contain 4 to 12 alphanumeric characters. Symbols
and spaces are not allowed, and the passwords are case-sensitive.
•
For
serial communication
, select
RS-232
and set the communications settings
to 38400 baud.
6.
Click the
Connect
button. If the connection is unsuccessful, an error message or
timeout message is displayed. If the connection is successful, the model name is
displayed within the dialog box and the
New Firmware File
panel becomes
accessible.
7.
Click the
Browse
button. The
Open
window appears.
8.
Locate and select the firmware file on your PC that you downloaded for the MLC, then
click the
Open
button. The
Open
window closes.
9.
Click
Add
. The
Add Device
dialog box closes, and the MLC you just added appears in
the device list within the main Firmware Loader window. The version of the currently installed
firmware, the name of the firmware file you selected to load onto the unit, and the IP address
are also listed.
10.
With that MLC unit selected, click
Begin
. The PC uploads the new firmware to the MLC.
Once the firmware is uploaded, the MLC restarts events.
11.
Firmware Loader displays the new firmware version in the
Firmware
column.
Summary of Contents for MLC 104 IP Plus Series