MLC 104 IP Plus Series • SIS
™
Pr
ogramming and Contr
ol
82
Command/Response Table for SIS Commands (continued)
Command
ASCII (Telnet)
(host to MLC)
URL Encoded (web)
(host to MLC)
Response
(MLC to host)
Additional Description
Set global Ethernet connection
timeout period
24
E
1*
X6(
TC
}
W 1 %2A
X6(
TC
|
Pti 1*
X6(
]
The global port timeout is the default timeout
period for all Telnet sessions.
NOTE:
You must be logged in as an administrator to change this setting.
View global connection timeout
period
E
1TC
}
W 1TC
|
X6(
]
IR port use
The following variables are used for these IR port commands:
X21%
= IR output port number:
01
= projector/display port
Port numbers are two ASCII characters (2 bytes). For example, port 1 is represented as
01
(hex
30 31
).
X5&
= the IR file number (
0
-99), as in files
1.eir
,
2.eir
,
3.eir
, and so on,
stored in the controller. Each
.eir
file contains commands for a specific device.
X5*
= IR playback function number (1-137), of a specific function or command set
contained within the file.
IR function numbers
0
and 127 or higher can return information only.
0
= return all data
129
= manufacturer
130
= model
131
= class
132
= remote
133
= creation date
134
= comments
137
= user file name
(a descriptive name the user/
installer gave the file).
X5(
= IR playback mode
0
= play once
1 = play continuously
2 = stop.
Send an IR command
28
E
X21%
,
X5&
,
X5*
,
X5(
IR
}
Send an IR command via IR output port
number
X21%
.
The response includes leading zeros.
W
X21%
%2C
X5&
%2C
X5*
%2C
X5(
IR
|
Irs
X21%
,
X5&
,
X5*
,
X5(
]
NOTE:
To stop mode 1 IR command playback (continuous playback), send the IR command again but with playback mode (
X5(
) = 0.
Get IR command info
13, 28
E X5&
,
X5*
IR
}
W
X5&
%2C
X5*
IR
|
{
descriptive text
}
]
The response to this command is the name/
description (such as Power On, Power Off,
Enter, Play, Stop, RGB, Menu) of the specific
command you ask about.
Example:
E
3,1IR
}
W3%2C1IR
|
POWER
]
Command/function 1 in file
3.eir
is the
Power command.
Example:
E
3,2IR
}
W3%2C2IR
|
E13
]
Command/function 2 in file
3.eir
is not
defined or does not exist, so the controller
returns E13, the invalid value error number.
NOTE:
An IR driver must be loaded into the MLC before IR command information can be read.
Summary of Contents for MLC 104 IP Plus Series
Page 6: ......