MLC 104 IP Plus Series • SIS
™
Programming and Control
100
The syntax for setting a special function for an MLC is
X?
* __ # where
X?
is the value and
__ is the function number. To view the setting of a function, use __#, where __ is the function
number. In the following table the values of the
X?
variable are different for each command
or function. These values are given in the rightmost column.
Command/Response Table for Special Function SIS Commands
Command
ASCII
Command
(host to MLC)
Response
(MLC to host)
X?
values
and additional descriptions
Delay times
Most projectors require a certain amount of time during warm-up and cool-down during which they do not accept
commands. Once you have set the input selection lock during power on/off command (
command (
1#
) to specify the amount of time for the MLC to wait between sending the projector a power-on or power-off
command and when the next input button press can occur.
Power on delay
24
X?
*1#
WarmUp*
X?]
0 = 0 seconds,
1 = 2 seconds,
2 = 4 seconds,
... in 2 second steps up to
150 = 300 seconds (5 minutes).
Example:
8*1#
WarmUp*008
Example:
set a 16 second power
on delay.
Example:
1#
WarmUp*023
Example:
view the power on delay
setting (23 = 46 seconds).
Power off delay
24
X?
*2#
CoolDown*
X?]
0
= 0 seconds,
1
= 2 seconds,
2
= 4 seconds,... in 2 second
steps up to
150
= 300 seconds.
Example:
23*2#
CoolDown*023
]
Example:
set a 46 second power
off delay.
Power off button delay
24
X?
*22#
PwrOffDly*
X?]
0
= the power off button requires
no hold delay (default),
1
= the power off button requires
a 2-second hold delay before
starting the power-off sequence.
Audio settings
Limit audio level on display power-
on
24
X?
*11#
VolLimit*
X?]
If this feature is enabled, the
maximum initial power-up volume
level does not exceed the level
specified by this command.
0
= audio off, ...,
20
= default value, ...,
100
= no limit on audio level at
power-on.
NOTE:
The MLC responds with an E14 error code when volume mode =
1
(increment/decrement).
NOTE:
The maximum is limited by the maximum volume setting (
, see page 106). If the maximum volume
(
command) is set, the limit audio level feature (
11#
command) is automatically set to 25% of the
).
Example:
28*11#
VolLimit*028
]
Example:
limit power-up volume to
28% of maximum volume.