MLC 104 IP Plus Series • Software-based Configuration and Control
43
5.
Change the IP address of the
PC
so it can communicate with the MLC, and change the
IP settings of the controller (see images below).
a.
Click the
Use the following IP address
button.
b.
Enter the following values, as shown in the following images for Windows XP (left)
and Windows 7 (right):
IP address:
192.168.254.253
Subnet mask:
255.255.0.0
Default gateway:
blank or 0.0.0.0
c.
Click
OK
to save the changes and exit the network setup. Reboot the PC, if
required, for the changes to become effective.
6.
Plug one end of a CAT 5 Ethernet crossover cable into the LAN connector on the MLC.
Plug the other end of the Ethernet cable into the Ethernet port on the PC.
NOTE:
If a network hub or switch is used between the PC and the MLC, use
a straight-through CAT 5 cable instead of a crossover cable (see
pin assignments on page 29).
7.
Set up the IP address of the MLC using a web browser, or SIS commands as described
earlier in this section.
8.
Restore the previous IP configuration for the PC by following steps
1
,
2
,
3
, and
5
but
use the original IP address settings for the PC that you wrote down in step
4
.
Summary of Contents for MLC 104 IP Plus Series