MLC 104 IP Plus Series • SIS
™
Pr
ogramming and Contr
ol
86
Command/Response Table for SIS Commands (continued)
Command
ASCII (Telnet)
(host to MLC)
URL Encoded (web)
(host to MLC)
Response
(MLC to host)
Additional Description
Request status of attached hardware
32I
32I
P1##
•
P2##
•
K1##
•
K2##
•
K3##
•
K4##
•
S**
]
or
P1##
•
P2##
•
K1##
•
K2##
•
K3##
•
K4##
•
S**
•
IPI???
]
Show the absence of or types of connected
devices.
Prefixes for connected devices:
P1 = SCP #1, address 0
P2 = SCP #2, address 1
K1 = control module #1, address 0
K2 = control module #2, address 1
K3 = control module #3, address 2
K4 = control module #4, address 3
S = MediaLink device, typically a
slaved MLS switcher.
For :
00
= not present
01
= MLS 306
02
= MLS 506
03
= MLS 506MA 70 V
04
= MLS 506SA
05
= MLS 506MA 100 V
06
= MLS 100 A
07
= MLS 103 V
08
= MLS 103 SV
09
= MLS 102 VGA
10
= MLA-VC10
11
= MLS 304MA
12
= MLS 406
13
= MLS 406MA
14
= MLS 406SA
15
= MLS 304SA
16
= PVS 204SA
17
= PVS 204SA Plus
99
= unrecognized.
For ##:
00
= not present
01
= present (SCP)
or
IRCM-VCR
02
= IRCM-DVD
03
= IRCM DVD+
04
= ACM-Level
05
= ACM-Tone
06
= RCM-SC
07
= RCM-SCLT
08
= IRCM-Tape
09
= CM-5BB
10
= CM-20BB
11
= IRCM-DV+
12
= CM-9BLB
13
= CM-3BLB
14
= CM-19AC
99
= a device is present,
but unrecognized.
000
= not present
101
= IPI 101 AAP
104
= IPI 104 AAP.
For ???:
Examples:
32I
32I
P101
•
P200
•
K102
•
K201
•
K308
•
K407
•
S00
]
This example includes one SCP (
P101
), an
IRCM-DVD (
K102
), an IRCM-VCR (
K201
),
an IRCM-Tape (
K308
), and an RCM-SCLT
(
K407
). There is no slaved switcher.
32I
32I
P100
•
P201
•
K111
•
K211
•
K302
•
K401
•
S09
]
This example includes one SCP (
P201
), an
IRCM-DVD+ (
K111
and
K211
), an
IRCM-DVD (
K302
), an IRCM-VCR (
K401
),
and an MLS 102 VGA (
S09
).
IP setup commands
Set the unit name
24
E X1@
CN
}
W
X1@
CN
|
Ipn
•
X1@]
Change the MLC unit name to one of your
choosing (
X1@
), such as “AuditoriumMLC”,
“Rm316-AVcenter”, or “exec-boardroom-ctrl”.
NOTE:
The name consists of up to 24 alphanumeric characters (and the minus sign).
The first character must be a letter, the last character cannot be a minus sign
(hyphen). Spaces may not be used. Either case (upper, lower) is OK.
Set unit name to factory default
24
E
•
CN
}
W%20CN
|
Ipn
•
X4(]
X4(
= The name the MLC was shipped with:
MLC-104-IP-PLUS-##-##-##, a combination
of the model name and the last 3 pairs of hex
numbers in MAC address of the controller (for
example,
MLC-104-IP-PLUS-02-74-62
).
Read the unit name
E
CN
}
WCN
|
X1@]
or
X4(]
X1@
is the current, user-defined unit name of
the MLC.
X4(
is the factory default name of the MLC.
Summary of Contents for MLC 104 IP Plus Series