MLC 104 IP Plus Series • SIS
™
Pr
ogramming and Contr
ol
79
Command/Response Table for SIS Commands (continued)
Command
ASCII (Telnet)
(host to MLC)
URL Encoded (web)
(host to MLC)
Response
(MLC to host)
Additional Description
View lockout mode status
X
X
X20(]
Show lockout (executive mode) status.
X20(
=
0
(off, unlocked) or
3
(front panels,
control modules, and remote control locked/
disabled).
Example:
X
X
0
]
Example:
executive mode is off.
Status commands (an assortment)
View lamp hours status
6S
6S
X20%]
or
X20%
*
X20%]
X20%
represents the number of elapsed hours
of projector lamp use. The MLC responds
with two sets of lamp hours only if two lamp
hours have been set. If the status of a lamp
has not been set, it is shown as the default
(99999 hours) or “N/A”.
Set lamp hours status for 1 lamp
24
X20%
*6S
X20%
%2A6S
Lhr*
X20%
]
X20%
represents the five-digit numeric value
for elapsed lamp use hours, and it is used
by script to determine the number sent in
response to the “view lamp hours” command
(6S).
24
= The MLC responds with an E24 error
(privilege violation) if the connected user is not
logged in at administrator security level.
Set lamp hours status for 2 lamps
24
X20%
*
X20%
*6S
X20%
%2A
X20%
%2A 6S
Lhr*
X20%
*
X20%
]
Set display connection status
24
X21^
*7S
X21^
%2A 7S
Pcs
X21^]
This command resets the projector/display
connection status flag (
X21^
) used by scripts.
0
= projector not connected.
1
= projector is connected.
2
= undetermined status.
View connection status
7S
7S
X21^]
This command lets you know whether the
MLC scripts have determined if the display is
still connected to the MLC.
X21^
=
0
(disconnected),
1
(connected), or
2
(unknown).
View all voltages and
temperature status
11S
11S
responses from commands
12S
•
13S
•
14S
•
15S
•
16S
•
20S
]
View all voltages and the internal temperature
of the MLC at once. See the following six
commands below.
View +12 V power supply voltage
12S
12S
+
X20^]
Display the operating voltage of the power
input to the MLC.
X20^
= voltage in volts.
View +5 V IR receiver port voltage
13S
13S
+
X20^]
View +3.3 V IP Link/FPGA voltage
14S
14S
+
X20^]
View +1.5 V FPGA voltage
15S
15S
+
X20^]
View internal temperature status
20S
20S
X20&]
Display the internal operating temperature.
X20&
= temperature in degrees Celsius (the
response is 3 digits including leading zeros).
Summary of Contents for MLC 104 IP Plus Series