MLC 104 IP Plus Series • SIS
™
Pr
ogramming and Contr
ol
81
Command/Response Table for SIS Commands (continued)
Command
ASCII (Telnet)
(host to MLC)
URL Encoded (web)
(host to MLC)
Response
(MLC to host)
Additional Description
Configure serial port parameters
24
E X!
*
X2%
,
X2^
,
X2&
,
X2*
CP
}
Set baud rate (
X2%
), parity (
X2^
), data bits
(
X2&
), and stop bits (
X2*
) for port
X!
.
X!
= serial port number:
01
= front panel Config (RS-232 host) port
02
= Display RS-232/IR (projector) port
03
= MLS port (slaved or auxiliary switcher
00
= reserved or all ports.
X2%
= baud rate
(300, 600, 1200, 1800, 2400,
3600, 4800, 7200, 9600, 14400, 19200, 28800,
38400, 57600, or 115200 baud)
.
X2^
= parity (O = odd, E = even,
N = none [default], M = mark, S = space).
X2&
= data bits: 7, 8 (default = 8).
X2*
= stop bits: 1, 2 (default = 1).
W
X!
%2A
X2%
%2C
X2^
%2C
X2&
%2C
X2*
CP
|
Cpn
X!
•
Ccp
X2%
,
X2^
,
X2&
,
X2*
]
NOTE:
The MLC does not support flow control.
Example:
E
4*9600,N,8,1CP
}
W4%2A9600%2CN%2C8%2C1CP
|
Cpn4
•
Ccp9600,N,8,1
]
Set the projector control port for 9600 baud,
no parity, 8 data bits, and 1 stop bit.
View serial port parameters
E X!
CP
}
W
X!
CP
|
X2%
,
X2^
,
X2&
,
X2*
]
Example
E
2CP
}
W 2CP
|
9600,N,8,1
]
Configure receive timeout
24
E X!
*
X1&
*
X2)
*
X2#
*
X2!
CE
}
Set the
time to wait
(
X1&
= waiting time in
tens of ms until receipt of the first response
character before terminating the receive
operation,
X2)
= waiting time in tens of ms
between characters before terminating) and
priority status
(
X2#
:
0
= default, use
send data string
command parameters; 1 = use
configure
receive timeout
command parameters)
for
port
X!
.
X2!
= #L
or
#D (see previous page).
The response includes leading zeros.
W
X!
%2A
X1&
%2A
X2)
%2A
X2#
%2A
X2!
CE
|
Cpn
X!
•
Cce
X1&
,
X2)
,
X2#
,
X2!
]
View receive timeout
E X!
CE
}
W
X!
CE
|
X1&
,
X2)
,
X2#
,
X2!
]
Ethernet port configuration and use
NOTES:
•
X6(
and these timeout period commands are applicable only when the MLC is connected via Ethernet. If the MLC is connected via RS-232 protocol, only the global
timeout commands apply, and any commands involving
X6(
return the E13 error response.
•
If no data is received during the specified period, the Ethernet connection closes.
Set current Ethernet connection
timeout period
24
E
0*
X6(
TC
}
W 0 %2A
X6(
TC
|
Pti 0*
X6(
]
X6(
= IP timeout period specified in
10-second steps (1 - 65000, default =
30
=
300 seconds). Responses include leading
zeros.
The current port timeout period applies to the currently open Telnet session only. When you
start another Telnet session, it uses the default global port timeout period.
View current connection timeout
period
13
E
0TC
}
W 0TC
|
X6(
]
Summary of Contents for MLC 104 IP Plus Series
Page 6: ......