MLC 104 IP Plus Series • Special Applications
138
information on commands, see the
for Simple Instruction
Set (SIS) commands starting on page 77.
How these commands are typed into the Global Configurator Email Manager:
WCN
|
is the
SIS command
to read the unit
name of the
MLC.
WCI
|
is the SIS
command to
read the
IP address of
the MLC.
WCT
|
is the
SIS command
to read the date
and time.
2
1
3
Resulting e-mail that is sent out upon equipment disconnection:
<!--#echo var="W CN
|
"-->
results: unit name.
<!--#echo var="W CI
|
"-->
results: unit’s IP address.
<!--#echo var="W CT
|
"-->
results: date and time.
2
1
3
Your IPLink device (MLS-104-IP-PLUS-02-74-62 at 192.168.10.10) has detected unauthorized
equpment disconnection.
It is now Fri, 14 Dec 2007 16:02”34
SSI use in an MLC embedded web page
Reference notes:
An __
.shtml
file can be uploaded to the MLC by using one of the following:
•
The
File Management
tab of an MLC factory embedded web page
(http://<
IP address of the MLC
>/nortxe_index.html)
•
in the SIS section) via DataViewer,
Telnet, or HyperTerminal
•
A web browser by sending a Post command on port 80 followed by the delimited data
in the
.shtml
file