MLC 104 IP Plus Series • Software-based Configuration and Control
39
Configuring the MLC for Network Use Via a Web Browser
The default web pages that are preloaded on the MLC are compatible with popular web
browsers such as Microsoft Internet Explorer (version 5.5 or higher) or Mozilla Firefox (version
1.0 or higher). However, the MLC and the PC must both be part of the same subnet before
they can communicate via the LAN port. You must change the IP address of the PC to one
that is on the same subnet as the default IP address of the MLC (192.168.254.254).
NOTES:
•
This method requires a
crossover
cable (see
•
Make a note of the TCP/IP configuration of the host PC before changing its IP
address and make sure the PC and MLC are on the
same
subnet.
1.
Temporarily change the IP address of the host PC. See
IP Communication With an MLC 104 IP Plus
instructions.
2.
Obtain a valid IP address for the controller from your network administrator.
3.
Launch the web browser on the connected PC (for which you set up the network
configuration earlier), and enter
http://192.168.254.254/
in the address box. The
default web page of the MLC is displayed.
4.
Select the
Configuration
tab, then select
System Settings
from the menu on
the left of the screen. A web page appears. The top part of a typical screen is shown in
the following image.
5.
Set the MLC to the new IP address using either step
5a
or step
5b
.
a.
Enter the new IP address for the MLC, the corresponding subnet mask, and
the gateway address. IP addresses and subnet masks follow standard naming
and numbering conventions. The IP network administrator should provide the IP
addresses and subnet mask to be used with this controller.
b.
Select
DHCP On
.
6.
Click
Submit
. It takes a minute or more for the controller to store the new settings.
Once the IP address is changed, you lose communication with the controller.
7.
Close the browser.
8.
After changing the controller’s IP settings, change the TCP/IP settings of your PC back
to their original configuration.
Summary of Contents for MLC 104 IP Plus Series
Page 6: ......