MLC 104 IP Plus Series • Operation, Features, and Cabling
28
Power connection
5
PWR (power) connector
— To power the MLC, connect a cable between this port
and the included 12 VDC, 0.5 amp (maximum) power supply.
Alternatively, the MLC can be powered by an Extron PVS or MLS switcher. See
the diagrams for the
on page 27. Before powering the MLC from
a switcher, determine the combined power draw of the MLC and all connected
accessories to make sure it is lower than the power that can be provided by the
switcher.
Power supply wiring is shown in the following diagram.
Connecting an MLC 104 IP Plus to the External Power Supply
MLC 104 IP Plus
right side panel
MLS and
Power
ports
RS-232 12V
MLS PWR
A B
Rx
Tx
GROUND
GROUND
+12V IN
Power Supply
Output Cord
End View of
Power Supply
Output Cord
A
A
SECTION A–A
Strip wires
3/16" (5 mm)
max.
NOTE:
Check the polarity of the power
supply before connecting it to the MLC.
Power Input
Ground all
Devices
Ridged
Smooth
Ground
+12 VDC input
G
Power Input
Ground all
External Power Supply
(12 VDC, 0.5 A max.)
Power Input
• Connect to a 12 VDC, 0.5 A power supply.
• Front panel buttons light when the MLC receives power.
ATTENTION:
Risk of property damage:
ATTENTION :
Risque de dommages matériels :
•
Always use a power supply supplied or specified by Extron. Use of an
unauthorized power supply voids all regulatory compliance certification and
may cause damage to the supply and the end product.
•
Utilisez toujours une source d’alimentation fournie ou recommandée par
Extron. L’utilisation d’une source d’alimentation non autorisée annule toute
certification de conformité réglementaire, et peut endommager la source
d’alimentation et l’unité.
•
Unless otherwise stated, the AC/DC adapters are not suitable for use in air
handling spaces or in wall cavities.
•
Sauf mention contraire, les adaptateurs CA/CC ne conviennent pas à une
utilisation dans les espaces d’aération ou dans les cavités murales.
•
The installation must always be in accordance with the applicable provisions
of National Electrical Code ANSI/NFPA 70, article 725 and the Canadian
Electrical Code part 1, section 16. The power supply shall not be permanently
fixed to building structure or similar structure.
•
Cette installation doit toujours être conforme aux dispositions applicables du
Code américain de l’électricité (National Electrical Code) ANSI/NFPA 70, article
725, et du Code canadien de l’électricité, partie 1, section 16. La source
d’alimentation ne devra pas être fixée de façon permanente à la structure de
bâtiment ou à d’autres structures similaires.