MLC 104 IP Plus Series • SIS
™
Programming and Control
106
Command/Response Table for Special Function SIS Commands (continued)
Command
ASCII
Command
(host to MLC)
Response
(MLC to host)
X?
values
and additional descriptions
Front panel button LED control
24
X?
*
Y?
*51#
Lmp
Y?
*
X?]
This command controls which
LED(s) turn on or off or blink in a
specific button.
X?
is the LED state,
Y?
is which projector power,
input, or other button to control.
See the list of values at left or the
diagrams on pages
0
= all LEDs are off
1
= green LED is on
2
= red LED is on
3
= green & red LEDs are on
(button glows amber)
4
= slowly blinking green
5
= slowly blinking red
6
= slowly blinking amber
7
= fast blinking green
8
= fast blinking red
9
= fast blinking amber
1
= power on button
2
= power off button
9
= input button 1
10
= input button 2
11
= input button 3
12
= input button 4
To control the LEDs for
CM-3BLB or CM-9BLB
buttons, see the button
memory block map for
control modules (page 105).
X?
Y?
values
values
Query button LED control status
Y?
*51#
X?]
See the variables for the
command shown above.
NOTE:
) to set a button for an LED combination other than those
listed above for
X?
, the MLC responds with a zero (
0
). For example, if a button is set for its green LED to
blink slowly and its red LED to blink fast, the MLC sends
0
in response to the
Y?
*51#
command.
Miscellaneous settings
Enable switcher slaving
X?
*41#
Slave*
X?]
For
X?
,
0
= disable control of a slaved
Extron MLS switcher,
1
= enable (default) MLS slaved
switcher control.
Volume knob mode
24
X?
*46#
VolMode*
X?]
For
X?
,
0
= discrete volume values,
1
= continuous increment/
decrement.
Max. volume range
24
X?
*47#
VolMax*
X?]
For maximum volume,
X?
is
1
to
100
.
100
= default.
NOTE:
Maximum volume range cannot be changed while an MLS switcher is detected at the MLS switcher port
on the MLC.
NOTE:
When the maximum volume is changed, the volume level and the volume limit during display power-up
(
11#
) are set to 25% of the new maximum volume setting.
Volume encoder scale
24
X?
*49#
EncScale*
X?]
For
X?
:
0
= no scaling (default),
1
= decrease encoder speed
by 2,
2
= decrease encoder speed
by 3,
...,
255
= decrease encoder speed
by 256.
NOTE:
Use this command to slow down how fast the volume changes while
you turn the Volume knob or press a volume button on the remote
control. The more the encoder speed decreases, the more turns or
button presses it takes to change the volume by the same amount.