![EMC Connectrix ED-64M User Manual Download Page 269](http://html1.mh-extra.com/html/emc/connectrix-ed-64m/connectrix-ed-64m_user-manual_2399809269.webp)
A
Fibre Alliance MIB (fcmgmt.mib)
A-53
Using SNMP to Manage the Switch
FcConnUnitState
INTEGER
online and coming-online
will indicate online state
(2), and offline and
going-offline will indicate
offline state (3).
R
This object reports the overall state of
the connectivity unit. The meaning of all
values is essentially self-explanatory.
Any of these values may occur with any
of the fcConnUnitStatus values.
The values are defined as follows:
unknown (1), online (2), offline (3).
FcConnUnitStatus
INTEGER
This value will be mapped
from current status of
switch in such a way that
operational status indicates
ok (3), degraded status
indicates warning (4),
failed status indicate failed
(5).
R
This object reports the overall status of
the connectivity unit. The warning (4)
value means that the connectivity unit
needs attention; all other values are
essentially self-explanatory. Any of
these values may occur with any of the
fcConnUnitState values.
The values are defined as follows:
unknown (1), unused (2), ok (3),
warning(4), failed (5)
fcConnUnitProduct
SnmpAdminString
The oem product name.
R
The connectivity unit vendor’s product
model name.
FcConnUnitSerialNo
SnmpAdminString
OEM serial number.
R
The serial number identification for this
connectivity unit.
FcConnUnitUpTime
TimeTicks
R
The number of centiseconds since the
last unit initialization.
FcConnUnitUrl
DisplayString
Same as fcConnURL.
R/W
URL to launch a management
application, if applicable. Otherwise
empty string. In a standalone unit, this
would be the same as the top level
URL. This has the same definition as
systemURL for keywords.
FcConnUnitDomainId
OCTET STRING
(SIZE (3))
FFCCXX
where XX is the active
domainId of the switch.
R
24 bit Fibre Channel address ID of this
connectivity unit. Following the fibre
channel standard, the right-most bit of
the right-most octet is for the least
significant bit of the address value; the
left-most bit of the left-most octet, if
needed, is for the most significant bit of
the address value. If this value is not
applicable, all bits set to 1.
Table A-30
fcConnUnitTable (continued)
FA MIB Object Name
Type
Product Mapping
Access Description
Summary of Contents for Connectrix ED-64M
Page 4: ...Connectrix ED 64M User Guide iv...
Page 18: ...xviii Connectrix ED 64M User Guide Figures...
Page 26: ...xxvi Connectrix ED 64M User Guide Preface...
Page 30: ...xxx Connectrix ED 64M User Guide Warnings and Cautions...
Page 60: ...2 2 10 Connectrix ED 64M User Guide Operating the Director...
Page 86: ...3 3 26 Connectrix ED 64M User Guide Product Manager Overview...
Page 326: ...B B 8 Connectrix ED 64M User Guide Configuring Network Addresses...
Page 334: ...D D 6 Connectrix ED 64M User Guide Configuring Embedded Web Server Passwords...
Page 442: ...F F 4 Connectrix ED 64M User Guide Specifications...
Page 450: ...G G 8 Connectrix ED 64M User Guide Customer Support...