CPX230NWB ALARM CONTROL PANEL – INSTALLER MANUAL
119 / 144
EN
Opis
This is a low-level command which operates directly on the device
configuration memory. Sets mask bits in parameter
type_id,index
. This
command does not generate any events in addition to the information
that the configuration has been changed.
FOR:
CLEARMASK=0,65,0x01
Disable function
Premises lock
. When this function is turned off, the
user can arm and disarm the control panel again.
CLEARMASK=2,19,0x100
Disable function
Defaults restoral lock
. When this function is turned
off, it will be possible to restore the default installation engineer code
using the "PROG" button, located on the central, and from the
Configurator.
CLEARMASK=2,19,0 x 400
Turning off the
Allow quick arming without user authorisation
function. After turning this function off, the system can only be armed if
an access code is entered.
9.1.2.
General commands
They provide the execution of various tasks remotely, or the querying of certain parameters. If
the command is sent via SMS , the response is sent back to the telephone number from which
the command came. Do not send several commands in one SMS message or one frame, since
only one command will be executed , and it will not necessarily be the first command in the
list.
9.1.2.1.
DISC
Format:
DISC
Limitations:
Can be executed by ATS only
Description
Disconnects TCP connection with OSM server
9.1.2.2.
KILL
Format:
KILL
Limitations:
Can be executed by ATS only
Description
Restarts the GSM modem in the device. This results in breaking a GPRS
session and deregistration from the GSM network and re-registration to
GSM and GPRS network when you restart the modem.