System Account Number – ACN0
6.6.2.2.1.
If ACN0 number is set, it is attached to each system event sent to the monitoring
station. System events are those that provide information about the entire system, i.e.
power failure, modem reset, clock loss.
Partition Account Number – ACN1 (partition 1),ACN2 (partition 2)
6.6.2.2.2.
If numbers ACN1 and ACN2 are set, the ACN1 is attached to each non-system event
(with Partition ID 1 and/or 2) with information about partition 1, and to events with
information about Partition 2 – the ACN2. Non-system events are those with
information about particular partitions, i.e. about arming/disarming Partitions 1 and/or
2, alarms activated by triggering the detectors assigned to partitions.
If you enter an account number only for one of the partitions, you will not
be able to send settings to the control panel. Both ACN1, and ACN2 must
be provided.
Send system events to all accounts
6.6.2.2.3.
Selecting this option will send system events to all accounts, i.e. the system account,
partition 1 account and partition 2 account.