CPX230NWB ALARM CONTROL PANEL – INSTALLER MANUAL
39 / 144
EN
o
1 – NC mode
o
2 – NO mode
o
3 – EOL/NC mode
o
4 – EOL/NO mode
o
5 – DEOL/NC mode
o
6 – DEOL/NO mode
o
7 – Wireless mode
o
8 – TEOL mode
Example:
b)
change of a single parameter – operation mode of number 2 zone into NO
operation mode:
For Y=4
– number of alarms
Z
after which the zone will be automatically blocked
until re-arming (DEC type parameter). If 0, zone will not be blocked
.
For Y=5
– zone options (BIN type parameter), possible values for the parameter
Z
:
o
1 – zone ignored during arming – i.e. can be violated during partition arming
(e.g. delay zone shall be set to that option)
o
2 – generates alarm when violated after arming
o
3 – interlocking the zone (bypassing zone) if the zone violated when arming
(parameter “After time for exit”)
o
4 – enable/disable the function “Chime”. When the system is disarmed and 'chime
zone' is violated, all wired keypads make a beep sound. No report is sent to the
monitoring station.
For Y=6
– sensitivity
Z
in milliseconds, i.e. after what time the zones is considered to
change its status – default value for
Z
400ms.
Example:
c)
change of sensitivity of all zones into 200 milliseconds:
4.3.14.
Outputs configuration
Outputs, similar as zones, can be configured using complex service functions after
activation of which, all the parameters related to the relevant output can be given
subsequently or in a form of series of service functions that configure one output-related
parameter. Codes of output configuration functions are defined as per the following
pattern:
<XX> <Y>
<Z>
Note: For wireless zones 8 – 32 complex function 1XX0 should not
include option (function) 6 – sensitivity. Function 1XX3 (operation
mode) displays the value 7 for wireless zones 8 – 32, and the value
can not be changed.