9.1.5.
Commands for managing the wireless devices
9.1.5.1.
CPGETKEYFOBS/CPGETDETECTORS
Format:
CPGETKEYFOBS
CPGETDETECTORS
Limitations:
Can be executed by ATS
Description:
This command returns a list of all programmed wireless devices: key
fobs (CPGETKEYFOBS command) or wireless detectors
(CPGETDETECTORS command).
The command returns:
CMD:id:SERIALNO[,id:SERIALNO,...]
Where
id
is the device number, starting from 0. For remotes, it is the
remote number – 1 (i.e. id=0 corresponds to remote no. 1, id=1
corresponds to remote no. 2, etc.), for wireless detectors it is the zone
number – 1 (id=0 corresponds to detector no. 1, id=1 corresponds to
detector no. 2, etc.),
SERIALNO
is a 7-digit serial number of the device
in hexadecimal format (0–9 and A-F characters).
CMD:EEMPTY
If the database contains no devices of the specified type
-EBADSOURCE and NAK on protocol level,
If the command was sent by an unauthorised user
9.1.5.2.
CPDETECTORLOST
Format:
CPDETECTORLOST=?
CPDETECTORLOST=hours
Available since:
2.8.8
Limitations:
It can be carried out by the ATS and the installer if they have been
authorised to perform maintenance services