CPX230NWB ALARM CONTROL PANEL – INSTALLER MANUAL
75 / 144
EN
First alarm will be generated after the zone is returned and violated again.
6.3.1.7.
Ignore during arming
Zone can be violated during partition arming (e.g. delay zone shall be set to that option).
6.3.1.8.
Chime
The function “Chime” allows to inform the person in the room about violation of the input
zones (e.g. opening or closing the entrance door). When the system is disarmed and
'chime zone' is violated, all wired keypads make a beep sound. No report is sent to the
monitoring station
6.3.2.
Wireless zones (devices)
CPX230NWB is capable of storing information up to about 32 wireless inputs: A1 to A8, B1
to B8, C1 to C8, D1 to D8.
There are two ways to add detectors (described below).
The first way is to add the device to the list on the computer (by entering the serial
number) on which the Configurator is installed, and then to send all newly added devices
to the control panel.
When you press "Add to list" the following window appears: