CPX230NWB ALARM CONTROL PANEL – INSTALLER MANUAL
46 / 144
EN
9 – disable output 2
10 – disable output 3
11 – ambulance (available since Firmware above ver. 2.8.8)
12 – arm immediately (available since Firmware above ver. 2.10.0)
Note:
„Alarm” function is triggering an alarm with audible signal.
„Silent alarm” function is triggering an alarm without audible signal.
Switch on/off output 1, 2 and 3 functions allow control of any external devices.
„Ambulance” function works the same way as „HELP” button on the keypad, ie generates a
medical alarm.
“Arm immediately” function allows fully arming the system without counting down time for
exit (if is set).
Alarms from remote control can be generated regardless of whether or not the partition is
armed. For normal and silent alarm can be sent a message to the monitoring station,
depending on the configuration of the control panel.
Example:
a)
delete a remote control no. 1:
b)
add a remote control no. 1:
(press any key on the remote control)
4.3.17.2.
Delete all remote controllers
To remove all remote controllers from the system, enter the following function:
After entering the function PROG LED is blinking, the other LEDs are off. Pressing
key deletes all remote controllers, generating 3 beeps and exit the function. If you press
key will exit the function and remote controllers will not be erased.
4.3.18.
Emergency buttons
To configure emergency buttons, use the following pattern:
<XX> <Y>
<Z>
where:
XX
– defines the alarm button according to the coding:
00
– a change of settings of all alarm buttons
01
– FIRE button, activating the fire alarm
02
– HELP button, activating the medical alarm
03
– PANIC button, activating the break-in alarm