CPX230NWB ALARM CONTROL PANEL – INSTALLER MANUAL
44 / 144
EN
(press the sabotage button)
For Y=3
– Type of a wireless sensor (read only):
0 – no sensor
1 – PIR-10 sensor
2 – MC-10 sensor
4 – SD-10 sensor
5 – PIR-11 sensor
6 – SD-20 sensor
7 – KP2W keypad
8 – MC-11 sensor
9 – FL-10 sensor
12 – GS-21sensor
13 – GS-22 sensor
For Y=4
– Signal strength of wireless detectors. The function allows to check signal
strength of wireless detectors. LEDs 1 – 8 will display signal strength from selected
wireless detectors. No lighted LEDs indicates no signal.
1 LED – 12% signal strength
2 LEDs – 25% signal strength
3 LEDs – 37% signal strength
4 LEDs – 50% signal strength
5 LEDs – 62% signal strength
6 LEDs – 75% signal strength
7 LEDs – 88% signal strength
8 LEDs – 100% signal strength
At the same time, the keypad indicate the signal strength by a sound. 1 beep means
25% signal strength, 2 beeps means 50% signal strength, 3 beeps means 75% signal
strength, 4 beeps means 100% signal strength.
To exit the function press
(or
, if no key has been selected).
Note: During the adding a new wireless detector (function 2), the front
cover of the detector should be removed. It is recommended to add
wireless sensors individually. To prevent the accidental transmissions
from other detectors, only one detector cover should be removed
during the procedure of adding a new detector.
4.3.16.2.
Delete all wireless sensors
To remove all wireless sensors from the system, enter the following function:
After entering the function PROG LED is blinking, the other LEDs are off. Pressing
key deletes all wireless sensors, generating 3 beeps and exit the function. If you press
key will exit the function and detectors will not be erased.