CPX230NWB ALARM CONTROL PANEL – INSTALLER MANUAL
38 / 144
EN
For Y=0
– complex function, the initiation of which configures the parameters listed
below as another set of parameters;
Example:
a)
change of many parameters at the time for zone A1 using complex functions –
zone A1 is to be set as immediate circuit, in NC mode, to be blocked after 8
violations and generate alarm when violated after arming, with the 500ms
sensitivity:
For Y=1
– type of zone response (DEC type parameter). Options from 10 to 13 are
selected for longer (about 2 seconds) pressing the key from 0 to 3; possible values
for the parameter
Z
:
o
0 – instant
o
1 – delay
o
2 – 24h burglary
o
3 – arming/disarming by violation
o
4 – 24h tamper
o
5 – interior delayed
o
6 – 24h burglary silent
o
7 – 24h fire
o
8 – perimeter
o
9 – perimeter exit
o
10 – 24h gas
o
11 – 24h water leakage
o
12 – night (bypassed)
o
13 – night with prealarm
o
14 - arming/disarming by state change (available since the firmware version
2.10.0)
For Y=2
– delay
Z
in seconds for the zone of selected “delay” response type (DEC
type parameter). For other response types the parameter is irrelevant.
For Y=3
– operation mode (DEC type parameter), possible values for the parameter
Z
:
o
0 – unused zone
Note: In case of complex function (programming many parameters
at the time) after the parameter is entered and confirmed wit
,
the parameter is saved in the configuration memory and the system
waits for entering another parameter, and so on, until all
parameters of the complex service function are entered. Press
to cancel changes entered in currently configured parameter only
and exit service function – previously entered parameters,
confirmed with
, will not be cancelled.