CPX230NWB ALARM CONTROL PANEL – INSTALLER MANUAL
132 / 144
EN
9.1.4.
Commands for managing the partitions, zones and outputs
9.1.4.1.
CPGETSTATUS
Format:
CPGETSTATUS[=password]
Limitations:
You must know the administrator or user password. Can be executed by
ATS, administrator or user. If the command comes from ATS and was
not authorized with a code, enter the
password
.
Description
password is the system administrator or user password. The command
returns:
CPGETSTATUS:Ready,CurrentPartitionAlarms,alarmHistory,
otherAlarmHistory,zoneTampers,keypadTampers,zones,zonesLock,
partitions,outputs,batteryVoltage,powerSupplyVoltage,silentAlarms,
zonesComFailures,zonesPowerFailures,partitionsStayAway,partitionsNight
Where:
Ready
takes the value 1 if the system is ready for arming , 0 if it is not
ready.
CurrentPartitionAlarms
is a bit-vector determining whether the current
partitions are in alarm condition. Bit 0 corresponds to the first partition,
bit 1 corresponds to the second partition.
alarmHistory
a bit-vector indicating the alarm memory from the last
arming. Bit 1 (counting from 0), corresponding to the zone A1,… bit 32
corresponds to the zone D8.
otherAlarmHistory
a bit-vector indicating the additional alarm memory
from the last arming. Bit 1 (counting from 0), corresponding to the
tamper keypad 1, bit 2 corresponds to the tamper keypad 2, bit 3
corresponds to the tamper keypad 3, bit 7 corresponds to the alarm from
remote controls.
zoneTampers
is a bit-vector indicating the zone tampering. Bit 1
(counting from 0) means the zone A1.
keypadTampers
is the alarm from the keypads tampering. Bit 0 means
the keypad 1.
Zones
– means the current status of the zones. It is a bit-vector, where
the bit 1 (counting from 0) means the zone A1, bit 2 means the zone A2,
etc. If the zone is impaired, the bit is set.
zonesLock
– means the current status of the zone blockade. It is a bit-
vector, where bit 1 (counting from 0) means the zone A1, bit 2 means
the zone A2, etc. If the zone is blocked, the bit is set.
Partitions
– means the current status of the partitions. It is a bit-vector,
where bit 0 means the partition 1, the bit 1 the partition 2 (otherwise
than for the zones and outputs where bit 1 means the zone/output 1). If
the partition is armed or counts down, the time to output the
corresponding bit is set.
Outputs
– means the current status of outputs. It is a bit-vector, where
bit 1 (counting from 0) means the output 1, bit 2 means the output 2
and bit 3 means the output 3. If the output is enabled, the bit is set.
batteryVoltage
– battery voltage in mV (12000 = 12V). If the battery is