CPX230NWB ALARM CONTROL PANEL – INSTALLER MANUAL
87 / 144
EN
NOTE: If newly set codes are lost, it will be necessary to send the blocked
devices to the EBS technical service.
6.4.11.
Communication parameters lock
After checking that option changing:
service code (ATS)
turning on/off “Communication settings lock” option
server phone number
APN, user ID, user password
primary server port
secondary server port
SMS encryption key
GPRS encryption key
DNS server addresses
phone numbers, to which SMS messages will be forwarded
will require service code (ATS) knowledge!
As a result, it will be impossible to
register control panel in other monitoring station without authorization.
After activating this option, resetting to default settings via Configurator, will also require
service code (ATS).
On the other hand, installer will be able to:
change transmission parameters, e.g. GPRS and SMS test periods, SMS limits,
send it to control panel (with the exception of communication parameters written
above, which will be blocked),
read settings saved on the device,
save control panel settings to .emi file.
Default service code (ATS) is 0000 – it is recommended to change it to unique,
preferably 7-digit code. In case of losing this code it will be necessary to send
the device to EBS office.
6.4.12.
Allow quick arming without user authorization
When this function is selected, it is possible to quickly arm the system using a keypad,
without the need to enter the user authorisation code. Partial or complete disarming of
any part of the system will only possible using the sequence where the code is entered.
6.4.13.
After disarming disable alarm history notification
When this function is selected, after disarming the system (partition), past alarms from
zones assigned to partition (F diode blinking - partition 1, 6 diode - partition 2), after
assigned delay time, (refer to chapter 6.4.14) will cease to be shown on the keypad
(diodes will turn off). The user will retain access to state of the alarm memory from
inputs, by entering the 3# function, untill he chooses to delete it. If the system is armed,
and the alarm caused by any 24-hour zone will occur, then the fault memory can be
turned off by arming and disarming the system (if this option is checked) or by entering
the 3# keypad function and deleting the memory.