CPX230NWB ALARM CONTROL PANEL – INSTALLER MANUAL
37 / 144
EN
If diodes 1, 2 and 3 are turned off, it means the ACNs have not been set up. The ACN0
number is set by pressing button 3, keying in four hexadecimal characters and pressing the
confirmation button
. The ACN1 and ACN2 numbers are set in the same way. If the
diodes are turned on, pressing buttons 1, 2, 3 allows you to see the assigned numbers and
to change them if necessary.
NOTE: If you have assigned an account number only to one of the
partitions, the same number will be automatically assigned to the other
partition and to the system.
4.3.12.2.
Delating the ACN numbers and changing option settings
To delete numbers or set up system event messages, press:
<Button 1/2/3>
Where:
button 1
– means deleting the ACN0 number sent to the system account
button 2
– means deleting the ACN1 and ACN2 numbers sent to the partition 1 and 2
accounts
button 3
– set-up how system events are to be sent, where:
o
diode 3 is off – system events are sent only to the system account
o
diode 3 is on – system events are sent to all accounts
NOTE: If you have deleted the ACN0 number, the ACN1 and ACN2
numbers will be also deleted.
4.3.13.
Zones configuration
Wired and wireless zones can be configured using complex service functions, after
activation of which, all the parameters related to the relevant zone can be given
subsequently or in a form of series of service functions that configure one zone-related
parameter. Additional configuration of wireless zones is described in item 4.3.16.
Codes of zone configuration functions are defined as per the following pattern:
<XX> <Y>
<Z>
where:
XX –
zone number from
01
to
32
, the table below shows zones names and their
corresponding numbers:
Name A1 A2 A3 A4 A5 A6 A7 A8 B1 B2 B3 B4 B5 B6 B7 B8 C1 C2 C3 C4 C5 C6 C7 C8 D1 D2 D3 D4 D5 D6 D7 D8
Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
Entering number
00
will change the parameters for all zones in the system,
Y
– number of parameter related to a given zone,
Z
- number (or value) of the next parameter.