CPX230NWB ALARM CONTROL PANEL – INSTALLER MANUAL
41 / 144
EN
For Y=4 –
interval duration between two following chirps
Z
in milliseconds;
Example: change of interval duration between two following chirps of all zones into 500
milliseconds:
4.3.15.
Partitions configuration
Partition configuration can be configured similarly as zones and outputs, using complex
service functions after activation of which, all the parameters related to the relevant
partition can be given subsequently or in a form of series of service functions that
configure one partition-related parameter. Codes of partition configuration functions are
defined as per the following pattern:
<XX> <Y>
<Z>
where:
XX –
determines the number of partition from
01
to
02
; entering number
00
will change
the parameters for both partitions,
Y –
number of parameter related to a selected partition,
Z
- number (or value) of the next parameter;
For Y=0 –
complex function, the initiation of which configures the parameters listed
below as another set of parameters;
For Y=1 –
zones belonging to a partition (BIN parameter). A blinking group diode
(from A to D) means that the group is currently being shown. If other groups are
continuously lit, it means they contain zones assigned to the selected partition.
Diodes switched off means that no zones in the given group are assigned to the
defined partition. By pressing buttons from 1 to 8, the user can assign zones from
the given group to the selected partition. Switching between groups is possible using
the
button. No Z parameter; no Z parameter,
For Y=2 –
outputs belonging to partition (BIN type parameter), no Z parameter
,
For Y=3 –
time for leaving the partition
Z
in seconds (DEC type parameter),
For Y=4 –
alarm time in the partition
Z
in seconds (DEC type parameter),
For Y=5 –
partition options (BIN type parameter), possible values
Z
:
o
1 – Quiet signaling of time for entering (during counting the time for leaving, the
buzzer in a keypad is not active)
o
2 – Quiet signaling of time for leaving (during counting the time for leaving, the
buzzer in a keypad is not active)
Note: Chirp settings are common to all outputs.
The factory values for both parameters are 250 ms