CPX230NWB ALARM CONTROL PANEL – INSTALLER MANUAL
122 / 144
EN
(counting from 0) means the zone 1 , bit 2 the zone 2, etc. If the zone is
impaired, the bit is set.
Partitions
– means the current partition status. It is a bit-vector, where bit
0 means the partition 1 and bit 1 the partition 2 (otherwise than for the
zone and outputs where bit 1 means the zone /output 1). If the partition is
armed or counts down the time to output the corresponding bit is set.
Outputs
– means the current status of outputs. It is a bit-vector, where bit
1 (counting from 0) means the output 1, bit 2 the output 2 and bit 3 the
output 3. If the output is enabled the bit is set.
Battery_voltage
– battery voltage in mV (12000 = 12V). If the battery is
not connected, the readings may be incorrect, and be around 9V (9000)
voltage_AC
– AC voltage at the AC terminals of CPX230NWB (downstream
the transformer) in mV (18000 = 18V)
blocked_zones
– means the current status of the zone blockade. It is a bit-
vector, where bit 1 (counting from 0) means the zone A1, bit 2 the zone
A2 itd. If the zone is blocked, the bit is set.
9.1.2.10.
GETPARAM
Format:
GETPARAM=parameter
Limitations:
Parameter is equal to APN or UN or PW or Server or PORT or SMS or
SMSPERIOD or as
id_typu , index
, possible to execution only by ATS
Description
Allows you to retrieve the value of a proper configuration parameter. The
configuration parameters are described in the section on parameters. It is
a twin command with SETPARAM.
9.1.2.11.
CPGETALARMSHOWTIME
Format:
CPGETALARMSHOWTIME
Limitations:
Can be changed by ATS, the admin and the user
Description
The command is used to retrieve the time settings after which the
signalling of historical alarms is switched off. The time is counted down
from the moment the partition is disarmed.
The command returns:
CPGETALARMSHOWTIME: delay – if the function “After disarming disable
the historical alarm signalling” is active,
delay
is the time expressed in
seconds
CPGETALARMSHOWTIME: OFF – if the function “After disarming disable
the historical alarm signalling” is not active