manualshive.com logo in svg
background image

Series by 

BALBOA

TM

TM

CS6000B SERIES

Duplex Models   

Operation Manual

Содержание BALBOA CS6000B Series

Страница 1: ...Series by BALBOA TM TM CS6000B SERIES Duplex Models Operation Manual...

Страница 2: ...control being replaced you may still need to modify the plumbing to achieve proper alignment VH Series Versi Heat Heater configuration This series is designed to allow the heater to be positioned wit...

Страница 3: ...ystem Start Up Filtration Programming 21 Modes Behaviors 21 Operational Considerations 24 Spa Side Messages 25 26 TroubleShooting 26 27 Testing Sensors 28 System Plug Pinouts 28 System Data Label 29 W...

Страница 4: ...he terminal box Refer to NEC and local codes A bonding lug is provided on the control box to permit connection of a solid copper bonding conductor between this point and any equipment metal enclosures...

Страница 5: ...ecting means must be readily accessible to the tub occupant but installed at least 5 feet 1 5m from the tub water WARNING Do not install indoors This unit uses a gas heater that requires proper ventil...

Страница 6: ...installation may be installed at the electrical service panel or a separate sub panel Use copper conductors ONLY The ground must be sized following the National Electric Code Table 250 122 For Power c...

Страница 7: ...eptacle or use an extension cord Doing so will create hazardous conditions and or invalidate the warranty DO NOT USE AN EXTENSION CORD 15 AMP RECEPTACLE 20 AMP RECEPTACLE OPTION 1 15 20AMP CORD END GF...

Страница 8: ...add it to an open slot in the panel Option 3 shows the power from main service panel to a GFCI subpanel within line of site of the spa Note Most local codes will allow a GFCI subpanel to be a disconne...

Страница 9: ...ion instructions This illustration is meant to be a guide for Field Technicians and is not intended to override or substitute the instructions supplied with the circuit breaker GFCI TEST Ground Fault...

Страница 10: ...e heater to the foot brackets and remove from under the box The mounting studs are attached to adjustable clamps on the heater Loosen the clamps to adjust the stud locations to align with the slide br...

Страница 11: ...ng SENSOR BODY unless leaking cracked or damaged Thread sealer is not required when screwing the CAP to the SENSOR BODY hand tighten only A thread sealer such as teflon tape will be required if replac...

Страница 12: ...ay on when high speed pump s or blower is turned on IMPORTANT Always refer to the product data label located on top of the control box for specific electrical information Use copper conductors only as...

Страница 13: ...ng As shown below the control systems are shipped with the sensors secured to the heater assembly Remove the securing ties and route sensors through the access hole located above the heater connector...

Страница 14: ...PUMP ACCESSORY CORD CONFIGURATION The following wiring configuration is for single speed pump circuits circulation pumps ozones blowers and accessories Black Hot Line White Common Green Ground Black H...

Страница 15: ...puts as seen above in figure 1 If 240V output is required please utilize the chart below to configure the appropriate outputs for 240V For example to convert pump 1 to 240V move the red coded wire to...

Страница 16: ...is disabled while any high speed pump is running OFF position heater can run while any all high speed pumps are running A1 Test Mode OFF A2 Un P1 TE LT A7 Mode changes allowed A10 High Amp mode A9 No...

Страница 17: ...sition heater can run while any all high speed pumps or blowers are running Note Aux is required For no Aux use CS6100 series system Panel Button Positions Panel Button Assignments 1 1 2 3 4 2 3 4 1 P...

Страница 18: ...osition temperature is displayed in degrees Fahrenheit Note Panel layout is always Pump 2 Pump 1 Temp Light Table 1 of Pumps Blower Before Heat Disabled A2 A10 OFF OFF 0 ON OFF 1 OFF ON 2 ON ON 3 A1 T...

Страница 19: ...Assignments A1 Test Mode OFF A2 Mode changes allowed A7 See Table 1 A10 See Table 1 A9 Non Circ Mode A5 2 speed P1 A3 OFF A3 ON 1 2 3 4 1 Pump 2 Blower 2 Pump 1 3 Temp 4 Light Circuit Board Configura...

Страница 20: ...ne or pressure water filters make sure that the filter nut housing drain plug and air relief valve are closed and tight 5 Using a standard water hose fill the spa with fresh tap water to the level rec...

Страница 21: ...e spaside panel returns to solid and the spa will heat to set temperature Heat Indicator Heat Indicator 10 During Priming Mode press Jets button s repeatedly and be sure all pumps are free of air 11 O...

Страница 22: ...switch into Standard Mode Non Circ systems will turn on pump 1 low every 30 minutes for 2 minutes to measure water temperature ECONOMY Mode heats the spa to the set temperature only during filter cycl...

Страница 23: ...appear next to the Jets button when it is active For Spasides with one temperature button Press the Temp button once to display the set temperature To change the set temperature press the pad a second...

Страница 24: ...ement It also shows the mounted spa light with a replacement colored lens Colored lenses will further the enhancement of the light Simply snap on or off to change the mood of your spa Wall fitting ref...

Страница 25: ...eeze related damage is not covered by the warranty Winterizing Chemical Water Treatment Your dealer is familiar with local water conditions and which chemicals are compatible with and designed specifi...

Страница 26: ...5 minutes service organization Follow action required for dr message reset Press any No Message on display heater Message Action Required Spa Side Messages Test sensors possible defective sensor refer...

Страница 27: ...ler Pump Not Plugged In Plug in the Pump Air Lock in Plumbing System Bleed the system Restricted Flow Insure that the water shut off valves are open and that suction fittings are not blocked by debris...

Страница 28: ...Protection On Refer to Spa Side Messages Current Limiting On 120V Systems will not heat if High Speed or Blower is on Contact your local dealer No Power Reset breaker at service panel Low Water Flow...

Страница 29: ...s must be clean 3 If the spaside has the error message of SA or Sb this is an indication of a faulty sensor or possibly a faulty circuit board 4 With the power off to the spa unplug the two sensors fr...

Страница 30: ...ty service return defective products within the warranty period to Hydro Quip The Hydro Quip Limited Warranty is for service on the control box only Purchaser is responsible for removal or reinstallat...

Страница 31: ...30 Dealer Contact Address City Phone State Zip Date of Manufacture Notes Use this section to jot down any information you may need at a later date Notes...

Страница 32: ...85 0069 Rev 01 10 22...

Отзывы: