Страница 1: ...pproval 3 North American Hazardous Location Approval 4 Environment and Enclosure 5 Prevent Electrostatic Discharge 6 About the 1756 CNB and 1756 CNBR Series E Modules 6 Understand Standalone and Redundant Control 7 Before You Begin 8 Install or Remove the Module Under Power 14 Install the Module 15 Remove the Module 16 Connect the Module to the Network 17 Troubleshoot the Module 23 Interpret the M...

Страница 2: ...lation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automation Inc with respect to use of information circuits equipment or software described in this manual Reproduction of the contents of this manual in whole or in part without written permission of Rockwell Automation Inc is prohibi...

Страница 3: ...en in Annex II to this Directive The examination and test results are recorded in confidential report No 28 682 010 Compliance with the Essential Health and Safety Requirements has been assured by compliance with EN 50021 IMPORTANT This equipment is not resistant to sunlight or other sources of UV radiation The secondary of a current transformer shall not be open circuited when applied in Class I ...

Страница 4: ...le plus défavorable code de température le plus faible peut être utilisé pour déterminer le code de température global du système Les combinaisons d équipements dans le système sont sujettes à inspection par les autorités locales qualifiées au moment de l installation EXPLOSION HAZARD Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous Do not disconnec...

Страница 5: ...be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts The interior of the enclosure must be accessible only by the use of a tool Subsequent sections of this publication may contain additional information regarding specific enclosure ty...

Страница 6: ... normal operation Follow these guidelines when you handle this equipment Touch a grounded object to discharge potential static Wear an approved grounding wriststrap Do not touch connectors or pins on component boards Do not touch circuit components inside the equipment If available use a static safe workstation When not in use store the equipment in appropriate static safe packaging IMPORTANT Only...

Страница 7: ...mary modules The other chassis is called the secondary chassis and the modules in the chassis are called secondary modules These installation instructions discuss both standalone and redundant control read them carefully to distinguish the procedures and requirements for each type of control IMPORTANT If you use redundant control you must select the same ControlNet network address for each set of ...

Страница 8: ...the necessary components Know the type of ControlNet network There are two types of scheduled traffic networks for ControlNet single keeper networks and multi keeper networks 1756 CNB or 1756 CNBR 1756 A4 1756 A7 1756 A10 1756 A13 or 1756 A17 1756 PA72 75 or 1756 PB72 75 Power Supply 1786 TPR 1786 TPS 1786 TPYR or1786 TPYS 1 1 1786 TPS or 1786 TPYS taps recommended for network connections 1786 TP ...

Страница 9: ...ade the firmware of the module at MAC ID 01 to be multi keeper capable Refer to the ControlNet Modules in Logix5000 Control Systems User Manual publication CNET UM001 for more information 1756 CNB and 1756 CNBR Major Minor Revision Keeper Type A 1 xx Single keeper B 2 xx Multi keeper C 3 xx Single keeper C 4 xx Multi keeper D 5 xx Multi keeper D 7 xx Multi keeper E 10 xx Multi keeper E 11 xx Multi...

Страница 10: ...o identify the hardware components of the 1756 CNB and 1756 CNBR modules Module Features Backplane Connector Front View Side View Switches Network Address Module Status Alphanumeric Display Module Status Indicator ControlNet Network Channel Status Indicators Network Access Port Channel B BNC Connector 1756 CNBR only Channel A BNC Connector Channel A ...

Страница 11: ... you must specify a unique ControlNet network address for modules in a redundant chassis you must specify the same address for the secondary module that you specified for the corresponding primary module Side of Module Front of Module Top of Module This module s network address is 23 TIP You can select an address of 01 to 99 for modules in a standalone chassis or 01 to 98 for modules in redundant ...

Страница 12: ...upply is shown in the figure Chassis and Power Supply Chassis and Power Supply For information on installing these products refer to the table Chassis Installation Publications Chassis Installation Publications Chassis Type Chassis Installation Power Supply Power Supply Installation Series B 1756 A4 1756 A7 1756 A10 1756 A13 Publication 1756 IN080 1756 PA72 B Publication 1756 5 67 1756 PB72 B 1756...

Страница 13: ...u can also install multiple 1756 CNB and 1756 CNBR modules in the same chassis You can install as many modules as your power supply can accommodate such as the number for which the power supply is rated Chassis Slot Numbering IMPORTANT If you plan to install a redundant system you mustplace the primary and redundant modules in the same corresponding slot in their respective chassis For example if ...

Страница 14: ...tions WARNING When you insert or remove the module while backplane power is on an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous before proceeding Repeated electrical arcing causes excessive wear to contacts on both the module and its mating connector Worn contacts may create electrical resistance...

Страница 15: ...pressure check the alignment Forcing the module into the chassis can damage the backplane connector or the module Slide the module into the chassis Make sure the module backplane connector properly connects to the chassis backplane Align the circuit board with top and bottom guides in the chassis Circuit Board The module is properly installed when it is flush with the power supply or other install...

Страница 16: ...odule If you are replacing an existing module with an identical one and you want to resume identical system operation you must install the new module with the same ControlNet address in the same slot Upper Tab Push on the upper and lower tabs to disengage them Then slide the module out of the chassis ...

Страница 17: ...le ControlNet network using redundant media WARNING If you connect or disconnect the communications cable with power applied to this module or any device on the network an electrical arc can occur This could cause an explosion in hazardous location installations TIP Use the 1786 CP cable for temporary connections such as programming software For permanent connections use a tap 1756 CNBR Module in ...

Страница 18: ...o refer to the following documentation ControlNet Coax Tap Installation Instructions publication 1786 5 7 ControlNet Cable System Planning and Installation Manual publication CNET IN002 TIP For network connections we recommend taps with a straight connector 1786 TPS or 1786 TPYS because of the location of the BNC connectors on the bottom of the module ...

Страница 19: ... If you disconnect the tap from the module place the dust cap back on the straight or right angle connector to prevent the connector from accidentally contacting a metallic grounded surface If Your Node Supports Connect The Tap s Connector nonredundant media 1756 CNB to the channel A connector on the module channel B on the 1756 CNBR is not used 1 1 While both channels are active Rockwell recommen...

Страница 20: ...ubleshooting check the tap drop cable for the label indicating the attached segment before making your connection To work properly when you use modules in a redundant control chassis pair the primary and redundant partner modules must be connectedtothe samenetwork segment If youare using redundant media connect the channel of each partner to the same network segment Tap Segment 1 Segment 2 Tap Tap...

Страница 21: ...ialization No Yes INIT No Yes Module status indicator red INIT has failed and the module displays an error message Refer to Troubleshoot section Replace the module OR WAIT SRM Modules are in a redundant control chassis pair Initialization is complete The status indicator blinks green Channel A and B indicators alternately flash Channel A and B indicators display the network condition as listed on ...

Страница 22: ...C communication card and a 1786 CP cable Use a 1770 KFC communication interface a serial or parallel connection and a 1786 CP cable IMPORTANT To work properly the primary and redundant partner module must be connected to the same network segment If you are using redundant media connect the channel of each partner to the same network segment 1756 CNBR 1786 CP Cable 1784 KTC KTCx PCIC or PCC Card Co...

Страница 23: ...t have a unique network address Troubleshoot the Module The 1756 CNB and 1756 CNBR modules have the diagnostic indicators as shown ATTENTION Use a 1786 CP cable when connecting a programming terminal to the network through network access port NAP Using a commercially available RJ style cable could result in network failure Module Status Display See Pages 24 to 27 Module Status Indicator See Pages ...

Страница 24: ... an invalid ControlNet network address or 99 an invalid ControlNet network address if you are using redundant control See footnote at end of table 1 Optional see page 12 Turn chassis power supply off 2 Remove the module from the chassis 3 Set the network address switches to a unique address 01 99 or 01 98 if redundant control 4 Install the module in the chassis 5 If off turn chassis power supply o...

Страница 25: ... or rack slot address incorrect Replace the chassis STOP The module commanded to stop functioning by the redundancy module This occurs when a nonredundancy compliant module is placed into a redundant secondary chassis Remove nonredundancy compliant module from redundant secondary chassis and replace with redundancy compliant module WAIT SRM 2 The module waiting for the redundancy module to complet...

Страница 26: ...he module is primary with a disqualified secondary partner Check the type and revision of the 1756 CNB module PwQg 2 The module is primary with a qualifying secondary partner Redundant system status No action required PwQS 2 The module is primary with a qualified secondary partner PwNS 2 The module is primary with no secondary partner Check corresponding slot of secondary chassis for correct modul...

Страница 27: ... switchover phase 2 in progress SO_3 2 Old primary switchover phase 3 in progress SN_1 2 New primary switchover phase 1 in progress SN_2 2 New primary switchover phase 2 in progress SN_3 2 New primary switchover phase 3 in progress Cpt 2 the module has not determined if it is compatible Cpt 2 the module has determined that it is not compatible Replace the module with correct type and revision 1 If...

Страница 28: ...icator viewed independent of the other If both indicators are flashing they must flash together in phase The ControlNet Network Channel Status Indicators table summarizes the meanings of these states ControlNet Network Channel Status Indicators Cause Action Off No power None or power up Steady red Faulted unit Cycle power or reset unit If fault persists contact A B representative or distributor Al...

Страница 29: ...ck media For example broken cables loose connectors missing terminators No other nodes present on network Add other nodes to the network Flashing red green Incorrect network configuration Cycle power or reset unit If fault persists contact A B representative or distributor 1 The configuration manager node is the node responsible for distributing ControlNet network configuration data to all nodes o...

Страница 30: ...ctors for redundant media operation 1 NAP RJ 45 8 pin with shield Cable Quad shield RG 6 coaxial cable Ground isolation Transformer ControlNet network communication rate 5 M Diagnostics Yes Weight 1756 CNB 1756 CNBR 0 260 kg 0 57 lb 0 293 kg 0 64 lb Mounting type Chassis Mounting location 1756 ControlLogix Chassis Number of nodes max 99 Slot width 1 Connections supported max 64 Communication inter...

Страница 31: ...emperature IEC 60068 2 1 Test Ad Operating Cold IEC 60068 2 2 Test Bd Operating Dry Heat IEC 60068 2 14 Test Nb Operating Thermal Shock 0 60 C 32 140 F Storage temperature IEC 60068 2 1 Test Ab Unpackaged Nonoperating Cold IEC 60068 2 2 Test Bb Unpackaged Nonoperating Dry Heat IEC 60068 2 14 Test Na Unpackaged Nonoperating Thermal Shock 40 85 C 40 185 F Relative humidity IEC 60068 2 30 Test Db Unp...

Страница 32: ...Hz 10 V m with 200 Hz 50 Pulse 100 AM at 1890 MHz 1 V m with 1 kHz sine wave 80 AM from 2000 MHz 2700 MHz EFT B immunity IEC 61000 4 4 2 kV at 5 kHz on communications ports Surge transient immunity IEC 61000 4 5 2 kV line earth CM on communications ports Conducted RF immunity IEC 61000 4 6 10V rms with 1 kHz sine wave 80 AM from 150 kHz 80 MHz Enclosure type rating None open style Environmental Sp...

Страница 33: ...Class I Division 2 Group A B C D Hazardous Locations CE European Union 89 336 EEC EMC Directive compliant with EN 50082 2 Industrial Immunity EN 61326 Meas Control Lab Industrial Requirements EN 61000 6 2 Industrial Immunity EN 61000 6 4 Industrial Emissions EN 61131 2 Programmable Controllers Clause 8 Zone A B C TickAustralian Radiocommunications Act compliant with AS NZS CISPR 11 Industrial Emis...

Страница 34: ...ndustrial Automation Wiring and Grounding Guidelines 1770 4 1 ControlNet Modules in Logix5000 Control Systems CNET UM001 ControlLogix Chassis Installation Instructions 1756 IN080 ControlLogix Power Supplies Installation Instructions 1756 IN078 ControlLogix Power Supplies Installation Instructions 1756 IN596 ControlNet Coax Tap Installation Instructions 1786 5 7 ControlNet Coax Media Planning and I...

Страница 35: ...ControlLogix ControlNet Interface Module 35 Publication 1756 IN604A EN P February 2006 Notes ...

Страница 36: ...automation com Installation Assistance If you experience a problem with a hardware module within the first 24 hours of installation please review the information that s contained in this manual You can also contact a special Customer Support number for initial help in getting your module up and running New Product Satisfaction Return Rockwell tests all of its products to ensure that they are fully...