Chapter 16 PLC Function Applications
MS300
(High Speed Model)
16-6
When the external multifunctional input terminals (MI1 to MI7) are in PLC Mode select bit 0
(51) or PLC Mode select bit 1 (52), and the terminal contact is closed or open, it will
compulsorily switch to the PLC mode, and keypad switching will be ineffective.
Corresponding actions are as follows:
PLC mode
PLC Mode select bit 1 (52)
PLC Mode select bit 0 (51)
Using KPC-CC01
MS300
Disable PLC
0
OFF
OFF
PLC Run
PLC 1
OFF
ON
PLC Stop
PLC 2
ON
OFF
Maintain previous
state
Maintain previous
state
ON ON
Use of MS300 digital keypad to implement PLC functions
When the PLC screen switches to the PLC1 screen, this will trigger one PLC action,
and the PLC program start/stop can be controlled by communications via the WPL.
When the PLC screen switches to the PLC2 screen, this will trigger one PLC stop, and
the PLC program start/stop can be controlled by communications via the WPL.
The external terminal control method is the same as shown in the table above.
NOTE
When input/output terminals (MI1 to MI7) are included in the PLC program, these input/output
terminals will only be used by the PLC. As an example, when the PLC program controls Y0 during
PLC operation (PLC1 or PLC2), the corresponding output terminal relay (RA / RB / RC) will operate
in accordance with the program. At this time, the multifunctional input/output terminal setting will be
ineffective. Because these terminal functions are already being used by the PLC, the DI / DO / AO in
use by the PLC can be determined by looking at Pr. 02-52, 02-53, and 03-30.
When the PLC's procedures use special register D1040, the corresponding AO contact AFM1 will be
occupied,
Pr. 03-30 monitors the state of action of the PLC function analog output terminal; bit 0 corresponds to
the AFM1 action state.
Summary of Contents for VFD11AMS21AFSHA
Page 5: ...IV This page intentionally left blank...
Page 8: ...Chapter 1 Introduction MS300 High Speed Model 1 3 1 2 Model Name 1 3 Serial Number...
Page 20: ...Chapter 3 Installation MS300 High Speed Model 3 3...
Page 21: ...Chapter 3 Installation MS300 High Speed Model 3 4 This page intentionally left blank...
Page 24: ...Chapter 4 Wiring MS300 High Speed Model 4 3 4 1 Wiring...
Page 25: ...Chapter 4 Wiring MS300 High Speed Model 4 4 Figure 1...
Page 27: ...Chapter 4 Wiring MS300 High Speed Model 4 6 4 2 System Wiring Diagram...
Page 43: ...Chapter 6 Control Terminals MS300 High Speed Model 6 6 This page intentionally left blank...
Page 91: ...Chapter 8 Optional Cards MS300 High Speed Model 8 8 Frame F Fig 8 16...
Page 115: ...Chapter 9 Specification MS300 High Speed Model 9 10 This page intentionally left blank...
Page 123: ...Chapter 10 Digital Keypad MS300 High Speed Model 10 8 This page intentionally left blank...
Page 293: ...Chapter 13 Warning Codes MS300 High Speed Model 13 6 This page intentionally left blank...
Page 303: ...Chapter 14 Error Codes MS300 High Speed Model 14 10 This page intentionally left blank...