Chapter 11 Summary of Parameter Settings
MS300
(High Speed Model)
11-26
07 Special Parameters
Pr.
Explanation
Settings
Factory
Setting
07-00
Software brake level
230 V: 350.0~450.0 VDC
460 V: 700.0~900.0 VDC
370.0
740.0
07-01 DC brake current level
0~100 %
0
07-02 DC brake time at startup
0.0~60.0 sec.
0.0
07-03 DC brake time at stop
0.0~60.0 sec.
0.0
07-04 DC brake start frequency
0.0~1500.0 Hz
0.0
07-05 Voltage increasing gain
1~200 %
100
07-06
Restart after momentary power
loss
0: Stop operation
1: Speed tracking by the speed before the power loss
2: Speed tracking by minimum output frequency
0
07-07 Allowed power loss duration
0.0~20.0 sec.
2.0
07-08 Base block time
0.1~5.0 sec.
0.5
07-09 Current limit of speed tracking
20~200 %
100
07-10 Treatment of restart after fault
0: Stop operation
1: Speed tracking by current speed
2: Speed tracking by minimum output frequency
0
07-11 Restart times after fault
0~10
0
07-12 Speed tracking during start-up
0: Disabled
1: Speed tracking by maximum output frequency
2: Speed tracking by motor frequency at start
3: Speed tracking by minimum output frequency
0
07-13 dEb
function
selection
0: Disabled
1: dEb with auto accel. / decal., the frequency will not
return after power recovery
2: dEb with auto accel. / decal., the frequency will
return after power recovery
0
07-15 Dwell time at accel.
0.00 ~ 600.00 sec.
0.00
07-16 Dwell frequency at accel.
0.0~1500.0 Hz
0.0
07-17 Dwell time at decel.
0.00 ~ 600.00 sec.
0.00
07-18 Dwell frequency at decel.
0.0~1500.0 Hz
0.0
07-19 Fan
cooling
control
0: Fan always ON
1: Fan will be OFF after the AC motor drive stops 1
minute
2: When the AC motor drive runs, the fan is ON. When
the AC motor drive stops, the fan is OFF
3: Fan turns ON when the temperature attain around
60
o
C
3
Summary of Contents for VFD11AMS21AFSHA
Page 5: ...IV This page intentionally left blank...
Page 8: ...Chapter 1 Introduction MS300 High Speed Model 1 3 1 2 Model Name 1 3 Serial Number...
Page 20: ...Chapter 3 Installation MS300 High Speed Model 3 3...
Page 21: ...Chapter 3 Installation MS300 High Speed Model 3 4 This page intentionally left blank...
Page 24: ...Chapter 4 Wiring MS300 High Speed Model 4 3 4 1 Wiring...
Page 25: ...Chapter 4 Wiring MS300 High Speed Model 4 4 Figure 1...
Page 27: ...Chapter 4 Wiring MS300 High Speed Model 4 6 4 2 System Wiring Diagram...
Page 43: ...Chapter 6 Control Terminals MS300 High Speed Model 6 6 This page intentionally left blank...
Page 91: ...Chapter 8 Optional Cards MS300 High Speed Model 8 8 Frame F Fig 8 16...
Page 115: ...Chapter 9 Specification MS300 High Speed Model 9 10 This page intentionally left blank...
Page 123: ...Chapter 10 Digital Keypad MS300 High Speed Model 10 8 This page intentionally left blank...
Page 293: ...Chapter 13 Warning Codes MS300 High Speed Model 13 6 This page intentionally left blank...
Page 303: ...Chapter 14 Error Codes MS300 High Speed Model 14 10 This page intentionally left blank...