Chapter 12 Description of Parameter Settings
MS300
(High Speed Model)
12-05-3
When Pr. 05-24 is set to 1, the drive will select by Pr. 05-23 setting and current motor frequency,
and switch current motor to Y-connection or
-connection. Relevant parameter settings of the
motor can be switched simultaneously.
Pr. 05-25 is used to set the switch delay time of Y-connection /
-connection.
When output frequency reaches Y-connection /
-connection switch frequency, drive will delay by
Pr. 05-25 before multi-function output terminals are active.
Pr. 02-01~02-07=29
Pr. 02-13 = 31
Y- c onnec t ion s w it c h: c an be us ed f or w ide range mot or
Y -c onnec t ion f or low s peed: higher t orque c an be us ed f or rigid t apping
-c onnec t ion f or high s peed: higher t orque c an be us ed f or high-s peed drilling
Pr. 02-01~02-07=30
-c onnec t ion is f inis hed
Y-c onnec t ion is f inis hed
Pr. 02-13 = 32
-c onnec t ion c ont rol
Y-c onnec t ion c ont rol
U
V
W
MI 1
MI 2
R A
MR A
IM
W
V
U
X
Y
Z
Y-connection output
Pr. 02-13 = 31
Y-connection confirmation
input Pr. 02-01~0 = 29
7
△-
connect ion out put
Pr. 02-13 = 32
△
-connection confirmation
input Pr. 02-01~0 =
7
30
Free run stat us
O N
O N
O N
O N
Y swit ch error
-
△
Output frequency
2 seconds
Delay t ime
Pr. 05-23
Summary of Contents for VFD11AMS21AFSHA
Page 5: ...IV This page intentionally left blank...
Page 8: ...Chapter 1 Introduction MS300 High Speed Model 1 3 1 2 Model Name 1 3 Serial Number...
Page 20: ...Chapter 3 Installation MS300 High Speed Model 3 3...
Page 21: ...Chapter 3 Installation MS300 High Speed Model 3 4 This page intentionally left blank...
Page 24: ...Chapter 4 Wiring MS300 High Speed Model 4 3 4 1 Wiring...
Page 25: ...Chapter 4 Wiring MS300 High Speed Model 4 4 Figure 1...
Page 27: ...Chapter 4 Wiring MS300 High Speed Model 4 6 4 2 System Wiring Diagram...
Page 43: ...Chapter 6 Control Terminals MS300 High Speed Model 6 6 This page intentionally left blank...
Page 91: ...Chapter 8 Optional Cards MS300 High Speed Model 8 8 Frame F Fig 8 16...
Page 115: ...Chapter 9 Specification MS300 High Speed Model 9 10 This page intentionally left blank...
Page 123: ...Chapter 10 Digital Keypad MS300 High Speed Model 10 8 This page intentionally left blank...
Page 293: ...Chapter 13 Warning Codes MS300 High Speed Model 13 6 This page intentionally left blank...
Page 303: ...Chapter 14 Error Codes MS300 High Speed Model 14 10 This page intentionally left blank...