Chapter 11 Summary of Parameter Settings
MS300
(High Speed Model)
11-9
02 Digital Input / Output Parameters
Pr.
Explanation
Settings
Factory
Setting
02-00 2-wire / 3-wire operation control
0: No function
1: 2-wire mode 1, power on for operation control
(M1: FWD / STOP, M2: REV / STOP)
2: 2-wire mode 2, power on for operation control
(M1: RUN / STOP, M2: REV / FWD)
3: 3-wire, power on for operation control
(M1: RUN, M2: REV / FWD, M3: STOP)
4: 2-wire mode 1
,
fast start up
(M1: FWD / STOP, M2: REV / STOP)
5: 2-wire mode 2
,
fast start up
(M1: RUN / STOP, M2: REV / FWD)
6: 3-wire
,
fast start up
(M1: RUN, M2: REV / FWD, M3: STOP)
IMPORTANT
1.
In fast start up function, terminal output will
keep in ready status, drive will response to the
command immediately.
2.
When using fast start up function, the output
terminal will have higher voltage potentially.
1
02-01
Multi-function input command 1
(MI1)
0: No function
0
1: Multi-stage speed command 1 / multi-stage
02-02
Multi-function input command 2
(MI2)
position command 1
0
2: Multi-stage speed command 2 / multi-stage
02-03
Multi-function input command 3
(MI3)
position command 2
1
3: Multi-stage speed command 3 / multi-stage
02-04
Multi-function input command 4
(MI4)
position command 3
2
4: Multi-stage speed command 4 / multi-stage
02-05
Multi-function input command 5
(MI5)
position command 4
3
5: Reset
02-06
Multi-function input command 6
(MI6)
6: JOG operation (By KPC-CC01 or external
4
control)
02-07
Multi-function input command 7
(MI7)
7: Acceleration / deceleration speed inhibit
0
8: The 1
st
, 2
nd
acceleration / deceleration time
selection
9: The 3
rd
, 4
th
acceleration / deceleration time
selection
10: EF Input (Pr. 07-20)
11: B.B input from external (Base Block)
Summary of Contents for VFD11AMS21AFSHA
Page 5: ...IV This page intentionally left blank...
Page 8: ...Chapter 1 Introduction MS300 High Speed Model 1 3 1 2 Model Name 1 3 Serial Number...
Page 20: ...Chapter 3 Installation MS300 High Speed Model 3 3...
Page 21: ...Chapter 3 Installation MS300 High Speed Model 3 4 This page intentionally left blank...
Page 24: ...Chapter 4 Wiring MS300 High Speed Model 4 3 4 1 Wiring...
Page 25: ...Chapter 4 Wiring MS300 High Speed Model 4 4 Figure 1...
Page 27: ...Chapter 4 Wiring MS300 High Speed Model 4 6 4 2 System Wiring Diagram...
Page 43: ...Chapter 6 Control Terminals MS300 High Speed Model 6 6 This page intentionally left blank...
Page 91: ...Chapter 8 Optional Cards MS300 High Speed Model 8 8 Frame F Fig 8 16...
Page 115: ...Chapter 9 Specification MS300 High Speed Model 9 10 This page intentionally left blank...
Page 123: ...Chapter 10 Digital Keypad MS300 High Speed Model 10 8 This page intentionally left blank...
Page 293: ...Chapter 13 Warning Codes MS300 High Speed Model 13 6 This page intentionally left blank...
Page 303: ...Chapter 14 Error Codes MS300 High Speed Model 14 10 This page intentionally left blank...