Chapter 12 Description of Parameter Settings
MS300
(High Speed Model)
12-06-15
Status 1: The drive is in operation
When any phase is less than Pr. 06-47 setting level and exceeds Pr. 06-46 setting time, the
drive will execute according to Pr. 06-45 setting.
P r. 06 -46
P r.06 -4 7
O PH L
Drive’s st atus
OPHL detection
Outpu t current
Time
Operation command
Whe n OPHL, Pr06-45 acts
Status 2: The drive is in stop; Pr. 06-48 = 0; Pr. 07-02
≠
0
After the drive starts, DC brake will be applied according to Pr. 07-01 and Pr. 07-02. During this
period, OPHL detection will not be conducted. After DC brake is completed, the drive starts to
run, and conducts the OPHL protection as mentioned in status 1.
Pr.06 -46
Pr.0 6-4 7
O P HL
Pr.0 7-0 1
P r. 07 -02
Drive’s st atus
Operation command
OPHL detection
Outpu t current
Time
Whe n OPHL, Pr06-45 acts
Summary of Contents for VFD11AMS21AFSHA
Page 5: ...IV This page intentionally left blank...
Page 8: ...Chapter 1 Introduction MS300 High Speed Model 1 3 1 2 Model Name 1 3 Serial Number...
Page 20: ...Chapter 3 Installation MS300 High Speed Model 3 3...
Page 21: ...Chapter 3 Installation MS300 High Speed Model 3 4 This page intentionally left blank...
Page 24: ...Chapter 4 Wiring MS300 High Speed Model 4 3 4 1 Wiring...
Page 25: ...Chapter 4 Wiring MS300 High Speed Model 4 4 Figure 1...
Page 27: ...Chapter 4 Wiring MS300 High Speed Model 4 6 4 2 System Wiring Diagram...
Page 43: ...Chapter 6 Control Terminals MS300 High Speed Model 6 6 This page intentionally left blank...
Page 91: ...Chapter 8 Optional Cards MS300 High Speed Model 8 8 Frame F Fig 8 16...
Page 115: ...Chapter 9 Specification MS300 High Speed Model 9 10 This page intentionally left blank...
Page 123: ...Chapter 10 Digital Keypad MS300 High Speed Model 10 8 This page intentionally left blank...
Page 293: ...Chapter 13 Warning Codes MS300 High Speed Model 13 6 This page intentionally left blank...
Page 303: ...Chapter 14 Error Codes MS300 High Speed Model 14 10 This page intentionally left blank...