Chapter 12 Description of Parameter Settings
MS300
(High Speed Model)
12-05-2
Rated Speed of Induction Motor 2 (rpm)
Factory Setting: 1710
Settings 0~65535
1710 (60 Hz 4 poles); 1410 (50 Hz 4 poles)
It is used to set the rated speed of the motor according to motor nameplate.
Pole Number of Induction Motor 2
Factory Setting: 4
Settings 2~20
It is used to set the number of motor poles (must be an even number).
Set up Pr. 01-35 and Pr. 05-15 before setting up Pr. 05-04 to make sure motor operates normally.
No-load Current of Induction Motor 2 (A)
Unit:
Ampere
Factory Setting: #.##
Settings 0~ Pr. 05-13 factory setting
The factory setting is 40 % of the motor rated current.
Multi-motors (Induction)
Selection
Factory Setting: 1
Settings 1: Motor 1
2: Motor 2
3: Motor 3
4: Motor 4
It is used to set the motor that driven by the AC motor drive. Multi-motors selection only supports
V/F control mode.
Frequency for Y-connection /
ᇞ
-connection Switch of Induction Motor
Factory Setting: 600.0
Settings 0.0~1500.0 Hz
Y-connection /
ᇞ
-connection Switch of Induction Motor IM
Factory
Setting:
0
Settings 0: Disable
1: Enable
Delay Time for Y-connection /
ᇞ
-connection Switch of Induction Motor
Factory Setting: 0.200
Settings
0.000~60.000 sec.
Pr. 05-23~Pr. 05-25 are applied in the wide range motors and the motor coil will execute the
switch of Y-connection /
-connection as required. (The wide range motors are related to the
motor design. In general, it has higher torque at low speed with Y-connection and has higher
speed at high speed with
-connection)
Pr. 05-24 is used to enable / disable the switch of Y-connection /
-connection.
Summary of Contents for VFD11AMS21AFSHA
Page 5: ...IV This page intentionally left blank...
Page 8: ...Chapter 1 Introduction MS300 High Speed Model 1 3 1 2 Model Name 1 3 Serial Number...
Page 20: ...Chapter 3 Installation MS300 High Speed Model 3 3...
Page 21: ...Chapter 3 Installation MS300 High Speed Model 3 4 This page intentionally left blank...
Page 24: ...Chapter 4 Wiring MS300 High Speed Model 4 3 4 1 Wiring...
Page 25: ...Chapter 4 Wiring MS300 High Speed Model 4 4 Figure 1...
Page 27: ...Chapter 4 Wiring MS300 High Speed Model 4 6 4 2 System Wiring Diagram...
Page 43: ...Chapter 6 Control Terminals MS300 High Speed Model 6 6 This page intentionally left blank...
Page 91: ...Chapter 8 Optional Cards MS300 High Speed Model 8 8 Frame F Fig 8 16...
Page 115: ...Chapter 9 Specification MS300 High Speed Model 9 10 This page intentionally left blank...
Page 123: ...Chapter 10 Digital Keypad MS300 High Speed Model 10 8 This page intentionally left blank...
Page 293: ...Chapter 13 Warning Codes MS300 High Speed Model 13 6 This page intentionally left blank...
Page 303: ...Chapter 14 Error Codes MS300 High Speed Model 14 10 This page intentionally left blank...