Chapter 16 PLC Function Applications
MS300
(High Speed Model)
16-73
API
LN
Binary floating point number obtain logarithm
125
D
P
Bit device
Word device
16-bit command
-
-
-
-
32-bit command (9 STEP)
DLN
Continuous
execution type
DLNP
Pulse
execution type
Flag signal: none
X Y M K H KnX
KnY
KnM
T
C
D
S
*
*
*
D
*
Notes on operand usage:
Please refer to the function specifications table for each device in
series for the scope of device usage
S
: operation source device.
D
: operation results device.
Taking e =2.71828 as a base,
S
is the exponent in the EXP operation.
[
D
+1
,
D
]=EXP
[
S +1
,
S
]
Valid regardless of whether the content of
S
has a positive or negative
value. The designated register D must have a 32-bit data format. This
operation is performed using floating-point numbers, and
S
must therefore
be converted to a floating point number.
Content of operand
D
=e
S
; e=2.71828
,
S
is the designated source data
When M0 is On, the value of (D1, D0) will be converted to a binary floating
point number, which will be stored in register (D11, D10).
When M1 is On, the EXP operation is performed on the exponent of (D11,
D10); its value is a binary floating point number stored in register (D21,
D20).
M0
M1
DFLT D0 D10
DLN D10 D20
Summary of Contents for VFD11AMS21AFSHA
Page 5: ...IV This page intentionally left blank...
Page 8: ...Chapter 1 Introduction MS300 High Speed Model 1 3 1 2 Model Name 1 3 Serial Number...
Page 20: ...Chapter 3 Installation MS300 High Speed Model 3 3...
Page 21: ...Chapter 3 Installation MS300 High Speed Model 3 4 This page intentionally left blank...
Page 24: ...Chapter 4 Wiring MS300 High Speed Model 4 3 4 1 Wiring...
Page 25: ...Chapter 4 Wiring MS300 High Speed Model 4 4 Figure 1...
Page 27: ...Chapter 4 Wiring MS300 High Speed Model 4 6 4 2 System Wiring Diagram...
Page 43: ...Chapter 6 Control Terminals MS300 High Speed Model 6 6 This page intentionally left blank...
Page 91: ...Chapter 8 Optional Cards MS300 High Speed Model 8 8 Frame F Fig 8 16...
Page 115: ...Chapter 9 Specification MS300 High Speed Model 9 10 This page intentionally left blank...
Page 123: ...Chapter 10 Digital Keypad MS300 High Speed Model 10 8 This page intentionally left blank...
Page 293: ...Chapter 13 Warning Codes MS300 High Speed Model 13 6 This page intentionally left blank...
Page 303: ...Chapter 14 Error Codes MS300 High Speed Model 14 10 This page intentionally left blank...