Chapter 12 Description of Parameter Settings
MS300
(High Speed Model)
12-01-7
JOG Acceleration Time
JOG Deceleration Time
Factory Setting: 10.00 / 10.0
Settings Pr. 01-45 = 0: 0.00~600.00 sec.
Pr. 01-45 = 1: 0.0~6000.0 sec.
The acceleration time is used to determine the time required for the AC motor drive to accelerate
from 0 Hz to maximum output frequency (Pr. 01-00).
The acceleration / deceleration time is invalid when using Pr. 01-44 Auto
acceleration /
deceleration setting.
The acceleration / deceleration time 1, 2, 3, 4 are selected according to the multi-function input
terminals settings. The factory settings are accel. / decel. time 1.
When enable torque limits and stalls prevention function, the actual accel. / decel. time will be
longer than the above action time.
Please note that it may trigger the protection function (Pr. 06-03 Over-current stall prevention
during acceleration or Pr. 06-01 Over-voltage stall prevention) when setting of accel. / decel. time
is too short.
Please note that it may cause motor damage or drive protection enabled due to over current
during acceleration when the setting of acceleration time is too short.
Use suitable brake resistor (please refer to Chapter 07 Optional accessories) to decelerate in a
short time and prevent over-voltage.
When enable Pr. 01-24 ~ Pr. 01-27 (S-curve accel. / decel. begin and arrival time) , the actual
accel. / decel. time will be longer than the setting.
01-00
01-13,15,17,19,21
01-12,14,16,18,20
Frequency
Time
Max. Output
Frequency
Frequency
Setting
accel. time
decel. time
Accel./Decel. Time
JOG Frequency
Factory Setting: 6.0
Settings 0.0~1500.0 Hz
Both external terminal JOG and key “F1” on the keypad KPC-CC01 (optional) can be used to set
JOG function. When the JOG command is ON, the AC motor drive will accelerate from 0 Hz to
JOG frequency (Pr. 01-22). When JOG command is OFF, the AC motor drive will decelerate from
Jog frequency to stop. The JOG accel. / decel. time (Pr. 01-20, Pr. 01-21) is the time that
accelerates from 0.0 Hz to JOG frequency (Pr. 01-22). The JOG command cannot be executed
when the AC motor drive is running. In the same way, when the JOG command is executing,
other operation commands are invalid.
Summary of Contents for VFD11AMS21AFSHA
Page 5: ...IV This page intentionally left blank...
Page 8: ...Chapter 1 Introduction MS300 High Speed Model 1 3 1 2 Model Name 1 3 Serial Number...
Page 20: ...Chapter 3 Installation MS300 High Speed Model 3 3...
Page 21: ...Chapter 3 Installation MS300 High Speed Model 3 4 This page intentionally left blank...
Page 24: ...Chapter 4 Wiring MS300 High Speed Model 4 3 4 1 Wiring...
Page 25: ...Chapter 4 Wiring MS300 High Speed Model 4 4 Figure 1...
Page 27: ...Chapter 4 Wiring MS300 High Speed Model 4 6 4 2 System Wiring Diagram...
Page 43: ...Chapter 6 Control Terminals MS300 High Speed Model 6 6 This page intentionally left blank...
Page 91: ...Chapter 8 Optional Cards MS300 High Speed Model 8 8 Frame F Fig 8 16...
Page 115: ...Chapter 9 Specification MS300 High Speed Model 9 10 This page intentionally left blank...
Page 123: ...Chapter 10 Digital Keypad MS300 High Speed Model 10 8 This page intentionally left blank...
Page 293: ...Chapter 13 Warning Codes MS300 High Speed Model 13 6 This page intentionally left blank...
Page 303: ...Chapter 14 Error Codes MS300 High Speed Model 14 10 This page intentionally left blank...