16-5-2 Introduction to special relay functions (special M)
R/W items: RO: read only function; RW: read and write function
Special
M
Description of Function
R/W *
M1000 Operates monitor NO contact (contact a). NO while RUN, contact a. This contact
is On while in the RUN state.
RO
M1001 Operates monitor NC contact (contact b). NC while RUN, contact b. This contact
is Off while in the RUN state.
RO
M1002 Initiates a forward (the instant RUN is On) pulse. Initial pulse, contact a.
Produces a forward pulse the moment RUN begins; its width = scan cycle
RO
M1003 Initiates a reverse (the instant RUN is Off) pulse. Initial pulse, contact a.
Produces a reverse pulse the moment RUN ends; the pulse width = scan cycle
RO
M1004 Reserved
RO
M1005 Drive malfunction instructions
RO
M1006 Drive has no output
RO
M1007 Drive direction FWD(0)/REV(1)
RO
M1008
~
M1010
--
--
M1011 10 ms clock pulse
,
5 ms On / 5 ms Off
RO
M1012 100 ms clock pulse
,
50 ms On / 50 ms Off
RO
M1013 1 sec. clock pulse
,
0.5 s On / 0.5s Off
RO
M1014 1 min. clock pulse
,
30 s On / 30 s Off
RO
M1015 Frequency attained (when used together with M1025)
RO
M1016 Parameter read/write error
RO
M1017 Parameter
write
successful
RO
M1018 --
--
M1019 --
--
M1020 Zero
flag
RO
M1021 Borrow
flag
RO
M1022 Carry
flag
RO
M1023 Divisor is 0
RO
M1024 --
--
M1025
Drive frequency = set frequency (ON)
Drive frequency =0 (OFF)
RW
M1026 Drive operating direction FWD(OFF) / REV(ON)
RW
M1027 Drive
Reset
RW
M1028 --
--
M1029 --
--
M1030 --
--
M1031 --
--
M1032 --
--
M1033 --
--
M1034 --
--
M1035 --
--
M1036 --
--
M1037 --
--
M1038 MI7 count begins
RW
M1039 Reset MI7 count value
RW
M1040 Hardware power (Servo On)
RW
M1041 --
--
M1042 Quick
stop
RW
M1043 --
--
M1044
Pause (Halt)
RW
Summary of Contents for VFD11AMS21AFSHA
Page 5: ...IV This page intentionally left blank...
Page 8: ...Chapter 1 Introduction MS300 High Speed Model 1 3 1 2 Model Name 1 3 Serial Number...
Page 20: ...Chapter 3 Installation MS300 High Speed Model 3 3...
Page 21: ...Chapter 3 Installation MS300 High Speed Model 3 4 This page intentionally left blank...
Page 24: ...Chapter 4 Wiring MS300 High Speed Model 4 3 4 1 Wiring...
Page 25: ...Chapter 4 Wiring MS300 High Speed Model 4 4 Figure 1...
Page 27: ...Chapter 4 Wiring MS300 High Speed Model 4 6 4 2 System Wiring Diagram...
Page 43: ...Chapter 6 Control Terminals MS300 High Speed Model 6 6 This page intentionally left blank...
Page 91: ...Chapter 8 Optional Cards MS300 High Speed Model 8 8 Frame F Fig 8 16...
Page 115: ...Chapter 9 Specification MS300 High Speed Model 9 10 This page intentionally left blank...
Page 123: ...Chapter 10 Digital Keypad MS300 High Speed Model 10 8 This page intentionally left blank...
Page 293: ...Chapter 13 Warning Codes MS300 High Speed Model 13 6 This page intentionally left blank...
Page 303: ...Chapter 14 Error Codes MS300 High Speed Model 14 10 This page intentionally left blank...