Chapter 9 Specification
MS300
(High Speed Model)
9-3
230V series_3-phase (no built-in filter)
Model VFD_ _ _ _ _ _ _
ANSHA
ENSHA
7A5MS23 11AMS23 17AMS23
Applicable Motor Output (kW)
1.5
2.2
3.7
Applicable Motor Output (hp)
2
3
5
Output
Heavy duty
Rated Output Capacity (kVA)
2.9
4.2
6.5
Rated Output Current (A)
7.5
11
17
Carrier Frequency (kHz)
2~15 (default 6)
Input
Rated Input Current (A)
Heavy Duty
9
13.2
20.4
Rated Voltage / Frequency
3-phase AC 200V~240VAC (-15% ~ +10%) / 50/60Hz
Mains Input Voltage Range (VAC)
170~264
Mains Frequency Range (Hz)
47~63
Frame B1
C1
C1
AC Drive Weight (kg)
1.05 kg
1.24
1.24
Cooling Method
Fan cooling with fan kit
EMC Filter
Optional
IP Rating
VFD
_ _ _ _ _ _ _ A
NSHA: IP20
VFD
_ _ _ _ _ _ _
E
NSHA: IP40*
230V series_3-phase (no built-in filter)
Model VFD_ _ _ _ _ _ _
ANSHA
ENSHA
25AMS23 33AMS23 49AMS23 65AMS23
Applicable Motor Output (kW)
5.5
7.5
11
15
Applicable Motor Output (hp)
7.5
10
15.2
20
Output
Heavy duty
Rated Output Capacity (kVA)
9.5
12.6
18.7
24.8
Rated Output Current (A)
25
33
49
65
Carrier Frequency (kHz)
2~15 (default 6)
Input
Rated Input Current (A)
Heavy Duty
30
39.6
58.8
78
Rated Voltage / Frequency
3-phase AC 200V~240VAC (-15% ~ +10%) / 50/60Hz
Mains Input Voltage Range (VAC)
170~264
Mains Frequency Range (Hz)
47~63
Frame D1
E1
F1
AC Drive Weight (kg)
2.07
3.97
6.25
Cooling Method
Fan cooling with fan kit
EMC Filter
Optional
IP Rating
VFD
_ _ _ _ _ _ _ A
NSHA : IP20
VFD
_ _ _ _ _ _ _
E
NSHA : IP40*
NOTE
IP40*: The IP rating of wiring area (main circuit terminals and control terminals, frame B/C/D/E/F) and the vent near capacitor (frame C/D/E/F)
is IP20.
The value of the carrier frequency is a factory setting. To increase the carrier frequency, the current needs to be decreased. See derating
curve diagram of Pr. 06-55 for more information.
When a load is a shock or impact load, use a higher level model.
Summary of Contents for VFD11AMS21AFSHA
Page 5: ...IV This page intentionally left blank...
Page 8: ...Chapter 1 Introduction MS300 High Speed Model 1 3 1 2 Model Name 1 3 Serial Number...
Page 20: ...Chapter 3 Installation MS300 High Speed Model 3 3...
Page 21: ...Chapter 3 Installation MS300 High Speed Model 3 4 This page intentionally left blank...
Page 24: ...Chapter 4 Wiring MS300 High Speed Model 4 3 4 1 Wiring...
Page 25: ...Chapter 4 Wiring MS300 High Speed Model 4 4 Figure 1...
Page 27: ...Chapter 4 Wiring MS300 High Speed Model 4 6 4 2 System Wiring Diagram...
Page 43: ...Chapter 6 Control Terminals MS300 High Speed Model 6 6 This page intentionally left blank...
Page 91: ...Chapter 8 Optional Cards MS300 High Speed Model 8 8 Frame F Fig 8 16...
Page 115: ...Chapter 9 Specification MS300 High Speed Model 9 10 This page intentionally left blank...
Page 123: ...Chapter 10 Digital Keypad MS300 High Speed Model 10 8 This page intentionally left blank...
Page 293: ...Chapter 13 Warning Codes MS300 High Speed Model 13 6 This page intentionally left blank...
Page 303: ...Chapter 14 Error Codes MS300 High Speed Model 14 10 This page intentionally left blank...