Chapter 16 PLC Function Applications
MS300
(High Speed Model)
16-51
API
ZCP
S1
S2
S
D
Range comparison
11
D
P
Bit device
Word device
16-bit command (9 STEP)
ZCP
Continuous
execution type
ZCPP
Pulse
execution type
32-bit command (17 STEP)
DZCP
Continuous
execution type
DZCPP
Pulse
execution type
Flag signal: none
X Y M K H KnX
KnY
KnM
T
C
D
S1
*
*
*
*
*
*
*
*
S2
*
*
*
*
*
*
*
*
S
*
*
*
*
*
*
*
*
D
*
*
Notes on operand usage:
The content value of operand S1 is less than the content value of
S2 operand
The operand D occupies three consecutive points
S1
: Lower limit of range comparison.
S2
: Upper limit of range comparison.
S
: Comparative value.
D
: Results of comparison.
When the comparative value
S
is compared with the lower limit
S1
and
upper limit
S2
, the results of comparison are expressed in
D
.
When lower limit
S1
> upper limit
S2
, the command will use the lower limit
S1
to perform comparison with the upper and lower limit.
Size comparison is performed algebraically. All data is compared in the form of
numerical binary values. Because this is a 16-bit command, when b15 is 1, this
indicates a negative number.
When the designated device is M0, it automatically occupies M0, M1 and M2.
When X0=On, the ZCP command executes, and M0, M1 or M2 will be On. When
X0=Off, the ZCP command will not execute, and the state of M0, M1 or M2 will
remain in the state prior to X0=Off.
If
≥
,
≤
, or
≠
results are needed, they can be obtained via series/parallel
connections of M0-M2.
X0
M0
M1
M2
ZCP
If C10 < K10, M0 = On
If
K10 < C10 < K100, M1 = On
If C10 > K100, M2 = On
X0
K10
C10
M0
K100
=
=
To clear results of comparison, use the RST or ZRST command.
X0
M0
RST
M1
RST
M2
RST
X0
M0
ZRST
M2
Summary of Contents for VFD11AMS21AFSHA
Page 5: ...IV This page intentionally left blank...
Page 8: ...Chapter 1 Introduction MS300 High Speed Model 1 3 1 2 Model Name 1 3 Serial Number...
Page 20: ...Chapter 3 Installation MS300 High Speed Model 3 3...
Page 21: ...Chapter 3 Installation MS300 High Speed Model 3 4 This page intentionally left blank...
Page 24: ...Chapter 4 Wiring MS300 High Speed Model 4 3 4 1 Wiring...
Page 25: ...Chapter 4 Wiring MS300 High Speed Model 4 4 Figure 1...
Page 27: ...Chapter 4 Wiring MS300 High Speed Model 4 6 4 2 System Wiring Diagram...
Page 43: ...Chapter 6 Control Terminals MS300 High Speed Model 6 6 This page intentionally left blank...
Page 91: ...Chapter 8 Optional Cards MS300 High Speed Model 8 8 Frame F Fig 8 16...
Page 115: ...Chapter 9 Specification MS300 High Speed Model 9 10 This page intentionally left blank...
Page 123: ...Chapter 10 Digital Keypad MS300 High Speed Model 10 8 This page intentionally left blank...
Page 293: ...Chapter 13 Warning Codes MS300 High Speed Model 13 6 This page intentionally left blank...
Page 303: ...Chapter 14 Error Codes MS300 High Speed Model 14 10 This page intentionally left blank...