5 not present
6 not present
The
find
keyword displays the output of the
show
command beginning from the first occurrence of
specified text. The following example shows this command used in combination with the
show
linecard all
command.
Example of the
find
Keyword
Dell#show system brief | find 0
Stack MAC : 00:11:12:13:18:20
Reload-Type : normal-reload [Next boot : normal-reload]
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version
Ports
--------------------------------------------------------------------------------
----
1 Management online S3048-ON S3048-ON 9-8(0-28) 52
2 Member not present
3 Member not present
4 Member not present
5 Member not present
6 Member not present
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
---------------------------------------------------------------------------
1 1 down AC up 8128
1 2 absent absent 0
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed
--------------------------------------------------------------------------------
----
1 1 up up 9900
1 2 up up 9900
1 3 up up 9900
Speed in RPM
The
display
command displays additional configuration information.
The
no-more
command displays the output all at once rather than one screen at a time. This is similar to
the
terminal length
command except that the
no-more
option affects the output of the specified
command only.
The
save
command copies the output to a file for future reference.
NOTE: You can filter a single command output multiple times. The
save
option must be the last
option entered. For example:
Dell# command | grep regular-expression | except
regular-expression | grep other-regular-expression | find regular-expression
| save
.
48
Configuration Fundamentals
Summary of Contents for S4820T
Page 1: ...Dell Configuration Guide for the S4820T System 9 8 0 0 ...
Page 282: ...Dell 282 Control Plane Policing CoPP ...
Page 622: ...Figure 81 Configuring Interfaces for MSDP 622 Multicast Source Discovery Protocol MSDP ...
Page 623: ...Figure 82 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 623 ...
Page 629: ...Figure 86 MSDP Default Peer Scenario 2 Multicast Source Discovery Protocol MSDP 629 ...
Page 630: ...Figure 87 MSDP Default Peer Scenario 3 630 Multicast Source Discovery Protocol MSDP ...
Page 751: ...10 11 5 2 00 00 05 00 02 04 Member Ports Te 1 2 1 PIM Source Specific Mode PIM SSM 751 ...
Page 905: ...Figure 112 Single and Double Tag First byte TPID Match Service Provider Bridging 905 ...
Page 979: ...6 Member not present 7 Member not present Stacking 979 ...
Page 981: ...storm control Storm Control 981 ...
Page 1103: ...Figure 134 Setup OSPF and Static Routes Virtual Routing and Forwarding VRF 1103 ...