Description
Behavior at Peer Up
Behavior During Run
Time
Action to Take
Spanning tree mismatch
at port level
A syslog error message
is generated.
A one-time
informational syslog
message is generated.
Correct the spanning
tree configuration on
the ports.
System MAC mismatch
A syslog error message
and an SNMP trap are
generated.
A syslog error message
and an SNMP trap are
generated.
Verify that the unit ID of
VLT peers is not the
same on both units and
that the MAC address is
the same on both units.
Unit ID mismatch
The VLT peer does not
boot up. The VLTi is
forced to a down state.
A syslog error message
is generated.
The VLT peer does not
boot up. The VLTi is
forced to a down state.
A syslog error message
is generated.
Verify the unit ID is
correct on both VLT
peers. Unit ID numbers
must be sequential on
peer units; for example,
if Peer 1 is unit ID “0”,
Peer 2 unit ID must be
“1’.
Version ID mismatch
A syslog error message
and an SNMP trap are
generated.
A syslog error message
and an SNMP trap are
generated.
Verify the Dell
Networking OS software
versions on the VLT
peers is compatible. For
more information, refer
to the
Release Notes
for
this release.
VLT LAG ID is not
configured on one VLT
peer
A syslog error message
is generated. The peer
with the VLT configured
remains active.
A syslog error message
is generated. The peer
with the VLT configured
remains active.
Verify the VLT LAG ID is
configured correctly on
both VLT peers.
VLT LAG ID mismatch
The VLT port channel is
brought down.
A syslog error message
is generated.
The VLT port channel is
brought down.
A syslog error message
is generated.
Perform a mismatch
check after the VLT peer
is established.
Reconfiguring Stacked Switches as VLT
To convert switches that have been stacked to VLT peers, use the following procedure.
1.
Remove the current configuration from the switches. You will need to split the configuration up for
each switch.
2.
Copy the files to the flash memory of the appropriate switch.
3.
Copy the files on the flash drive to the startup-config.
4.
Reset the stacking ports to user ports for both switches.
5.
Reload the stack and confirm the new configurations have been applied.
1074
Virtual Link Trunking (VLT)
Summary of Contents for S4820T
Page 1: ...Dell Configuration Guide for the S4820T System 9 8 0 0 ...
Page 282: ...Dell 282 Control Plane Policing CoPP ...
Page 622: ...Figure 81 Configuring Interfaces for MSDP 622 Multicast Source Discovery Protocol MSDP ...
Page 623: ...Figure 82 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 623 ...
Page 629: ...Figure 86 MSDP Default Peer Scenario 2 Multicast Source Discovery Protocol MSDP 629 ...
Page 630: ...Figure 87 MSDP Default Peer Scenario 3 630 Multicast Source Discovery Protocol MSDP ...
Page 751: ...10 11 5 2 00 00 05 00 02 04 Member Ports Te 1 2 1 PIM Source Specific Mode PIM SSM 751 ...
Page 905: ...Figure 112 Single and Double Tag First byte TPID Match Service Provider Bridging 905 ...
Page 979: ...6 Member not present 7 Member not present Stacking 979 ...
Page 981: ...storm control Storm Control 981 ...
Page 1103: ...Figure 134 Setup OSPF and Static Routes Virtual Routing and Forwarding VRF 1103 ...