error-disabled: Fo 3/52
02:36:43: %RPM0-P:CP %IFMGR-5-OSTATE_DN:
Downstream interface set to UFD
error-disabled: Fo 3/56
02:36:43: %RPM0-P:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Fo
3/48
02:36:43: %RPM0-P:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Fo
3/52
02:36:43: %RPM0-P:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Fo
3/56
02:37:29: %RPM0-P:CP %IFMGR-5-ASTATE_DN: Changed interface Admin state to
down: Te 1/7
02:37:29: %RPM0-P:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Te
1/7
02:37:29 :
UFD: Group:3, UplinkState: DOWN
02:37:29: %RPM0-P:CP %IFMGR-5-OSTATE_DN:
Changed uplink state group state to
down: Group 3
02:37:29: %RPM0-P:CP %IFMGR-5-OSTATE_DN:
Downstream interface set to UFD
error-disabled: Fo 3/60
02:37:29: %RPM0-P:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Fo
3/60
02:38:31 :
UFD: Group:3, UplinkState: UP
02:38:31: %RPM0-P:CP %IFMGR-5-OSTATE_UP:
Changed uplink state group state to
up: Group 3
02:38:53: %RPM0-P:CP %IFMGR-5-OSTATE_UP:
Downstream interface cleared from
UFD error-disabled: Fo 3/48
02:38:53: %RPM0-P:CP %IFMGR-5-OSTATE_UP:
Downstream interface cleared from
UFD error-disabled: Fo 3/52
02:38:53: %RPM0-P:CP %IFMGR-5-OSTATE_UP:
Downstream interface cleared from
UFD error-disabled: Fo 3/56
02:38:53: %RPM0-P:CP %IFMGR-5-OSTATE_UP:
Downstream interface cleared from
UFD error-disabled: Fo 3/60
02:38:53: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Fo
3/48
02:38:53: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Fo
3/52
02:38:53: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Fo
3/56
02:38:53: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Fo
3/60
Displaying Uplink Failure Detection
To display information on the UFD feature, use any of the following commands.
• Display status information on a specified uplink-state group or all groups.
EXEC mode
show uplink-state-group [
group-id
] [detail]
–
group-id
: The values are from 1 to 16.
–
detail
: displays additional status information on the upstream and downstream interfaces in
each group.
• Display the current status of a port or port-channel interface assigned to an uplink-state group.
EXEC mode
Uplink Failure Detection (UFD)
1021
Summary of Contents for S4820T
Page 1: ...Dell Configuration Guide for the S4820T System 9 8 0 0 ...
Page 282: ...Dell 282 Control Plane Policing CoPP ...
Page 622: ...Figure 81 Configuring Interfaces for MSDP 622 Multicast Source Discovery Protocol MSDP ...
Page 623: ...Figure 82 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 623 ...
Page 629: ...Figure 86 MSDP Default Peer Scenario 2 Multicast Source Discovery Protocol MSDP 629 ...
Page 630: ...Figure 87 MSDP Default Peer Scenario 3 630 Multicast Source Discovery Protocol MSDP ...
Page 751: ...10 11 5 2 00 00 05 00 02 04 Member Ports Te 1 2 1 PIM Source Specific Mode PIM SSM 751 ...
Page 905: ...Figure 112 Single and Double Tag First byte TPID Match Service Provider Bridging 905 ...
Page 979: ...6 Member not present 7 Member not present Stacking 979 ...
Page 981: ...storm control Storm Control 981 ...
Page 1103: ...Figure 134 Setup OSPF and Static Routes Virtual Routing and Forwarding VRF 1103 ...