VmanQos : 0
VmanDualQos : 0
EcfmAcl : 0
FcoeAcl : 2
iscsiOptAcl : 0
ipv4pbr : 0
vrfv4Acl : 0
Openflow : 0
fedgovacl : 0
nlbclusteracl: 0
st-sjc-s5000-29#
Enabling the FCoE Transit Feature
The following sections describe how to enable FCoE transit.
NOTE: FCoE transit is disabled by default. To enable this feature, you must follow the
.
As soon as you enable the FCoE transit feature on a switch-bridge, existing VLAN-specific and FIP
snooping configurations are applied. The FCoE database is populated when the switch connects to a
converged network adapter (CNA) or FCF port and compatible DCB configurations are synchronized. By
default, all FCoE and FIP frames are dropped unless specifically permitted by existing FIP snooping-
generated ACLs. You can reconfigure any of the FIP snooping settings.
If you disable FCoE transit, FIP and FCoE traffic are handled as normal Ethernet frames and no FIP
snooping ACLs are generated. The VLAN-specific and FIP snooping configuration is disabled and stored
until you re-enable FCoE transit and the configurations are re-applied.
Enable FIP Snooping on VLANs
You can enable FIP snooping globally on a switch on all VLANs or on a specified VLAN.
When you enable FIP snooping on VLANs:
• FIP frames are allowed to pass through the switch on the enabled VLANs and are processed to
generate FIP snooping ACLs.
• FCoE traffic is allowed on VLANs only after a successful virtual-link initialization (fabric login FLOGI)
between an ENode and an FCF. All other FCoE traffic is dropped.
• You must configure at least one interface for FCF (FCoE Forwarder) mode on a FIP snooping-enabled
VLAN. You can configure multiple FCF trusted interfaces in a VLAN.
• A maximum of eight VLANS are supported for FIP snooping on the switch. When enabled globally, FIP
snooping processes FIP packets in traffic only from the first eight incoming VLANs. When enabled on
a per-VLAN basis, FIP snooping is supported on up to eight VLANs.
Configure the FC-MAP Value
You can configure the FC-MAP value to be applied globally by the switch on all or individual FCoE VLANs
to authorize FCoE traffic.
The configured FC-MAP value is used to check the FC-MAP value for the MAC address assigned to
ENodes in incoming FCoE frames. If the FC-MAP value does not match, FCoE frames are dropped. A
session between an ENode and an FCF is established by the switch-bridge only when the FC-MAP value
on the FCF matches the FC-MAP value on the FIP snooping bridge.
366
FCoE Transit
Summary of Contents for S4820T
Page 1: ...Dell Configuration Guide for the S4820T System 9 8 0 0 ...
Page 282: ...Dell 282 Control Plane Policing CoPP ...
Page 622: ...Figure 81 Configuring Interfaces for MSDP 622 Multicast Source Discovery Protocol MSDP ...
Page 623: ...Figure 82 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 623 ...
Page 629: ...Figure 86 MSDP Default Peer Scenario 2 Multicast Source Discovery Protocol MSDP 629 ...
Page 630: ...Figure 87 MSDP Default Peer Scenario 3 630 Multicast Source Discovery Protocol MSDP ...
Page 751: ...10 11 5 2 00 00 05 00 02 04 Member Ports Te 1 2 1 PIM Source Specific Mode PIM SSM 751 ...
Page 905: ...Figure 112 Single and Double Tag First byte TPID Match Service Provider Bridging 905 ...
Page 979: ...6 Member not present 7 Member not present Stacking 979 ...
Page 981: ...storm control Storm Control 981 ...
Page 1103: ...Figure 134 Setup OSPF and Static Routes Virtual Routing and Forwarding VRF 1103 ...