NOTE: The system reboots when the offline diagnostics complete. This is an automatic
process. The following warning message appears when you implement the
offline stack-
unit
command:
Warning - Diagnostic execution will cause stack-unit to
reboot after completion of diags. Proceed with Offline-Diags [confirm
yes/no]:y
After the system goes offline, you must reload or run the
online stack-unit
stack-unit-number
command for the normal operation.
2.
Confirm the offline status.
EXEC Privilege mode
show system brief
3.
Start diagnostics on the unit.
diag stack-unit
stack-unit-number
When the tests are complete, the system displays the following message and automatically reboots
the unit.
Dell#00:09:42 : Diagnostic test results are stored on file: flash:/
TestReport-SU-0.txt
Diags completed... Rebooting the system now!!!
Mar 12 10:40:35: %S4820:0 %DIAGAGT-6-DA_DIAG_DONE: Diags finished on stack
unit 0
Diagnostic results are printed to a file in the flash using the filename format
TestReport-SU-<stack-
unit-id>.txt
.
Log messages differ somewhat when diagnostics are done on a standalone unit and on a stack
member.
4.
View the results of the diagnostic tests.
EXEC Privilege mode
show file flash://TestReport-SU-
stack-unit-id
.txt
Examples of Running Offline Diagnostics
The following example shows the
offline stack-unit
stack-unit-number
command.
Dell#offline stack-unit 0
Warning - offline of unit will bring down all the protocols and
the unit will be operationally down, except for running Diagnostics.
Please make sure that stacking is not configured for Diagnostics execution.
Also reboot/online command is necessary for normal operation after the offline
command is issued.
Proceed with Offline [confirm yes/no]:yes
Dell#Mar 12 10:32:18: %STKUNIT0-M:CP %CHMGR-2-STACKUNIT_DOWN: Stack unit 0 down
- stack unit offline
The following example shows the
show system brief
command.
Dell#show system brief
Stack MAC : 00:01:e8:8b:5d:8c
Reload-Type : normal-reload [Next boot : normal-reload]
-- Stack Info --
S-Series Debugging and Diagnostics
1145
Summary of Contents for S4820T
Page 1: ...Dell Configuration Guide for the S4820T System 9 8 0 0 ...
Page 282: ...Dell 282 Control Plane Policing CoPP ...
Page 622: ...Figure 81 Configuring Interfaces for MSDP 622 Multicast Source Discovery Protocol MSDP ...
Page 623: ...Figure 82 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 623 ...
Page 629: ...Figure 86 MSDP Default Peer Scenario 2 Multicast Source Discovery Protocol MSDP 629 ...
Page 630: ...Figure 87 MSDP Default Peer Scenario 3 630 Multicast Source Discovery Protocol MSDP ...
Page 751: ...10 11 5 2 00 00 05 00 02 04 Member Ports Te 1 2 1 PIM Source Specific Mode PIM SSM 751 ...
Page 905: ...Figure 112 Single and Double Tag First byte TPID Match Service Provider Bridging 905 ...
Page 979: ...6 Member not present 7 Member not present Stacking 979 ...
Page 981: ...storm control Storm Control 981 ...
Page 1103: ...Figure 134 Setup OSPF and Static Routes Virtual Routing and Forwarding VRF 1103 ...