About Your System
21
NOTE:
If your system fails to boot, press the System ID button for at least five
seconds until an error code appears on the LCD. Record the code, then see "Getting
Help" on page 167.
Table 1-6.
LCD Status Messages
Code
Text
Causes
Corrective Actions
N/A
SYSTEM NAME
A 62-character string that
can be defined by the user in
the System Setup program.
The SYSTEM NAME
displays under the
following conditions:
• The system is powered on.
• The power is off and
active POST errors are
displayed.
This message is for
information only.
You can change the system
ID and name in the
System Setup program.
See "Using the System
Setup Program" on
page 45.
E1000
FAILSAFE,
Call Support
See "Getting Help" on
page 167.
E1114
Temp Ambient
Ambient system
temperature is out of
acceptable range.
See "Troubleshooting
System Cooling Problems"
on page 140.
E1116
Temp Memory
Memory has exceeded
acceptable temperature
and has been disabled to
prevent damage to the
components.
See "Troubleshooting
System Cooling Problems"
on page 140.
E12
nn
xx
PwrGd
Specified voltage regulator
has failed.
See "Getting Help" on
page 167.
E1210
CMOS Batt
CMOS battery is missing,
or the voltage is out of
acceptable range.
See "Troubleshooting the
System Battery" on
page 138.
E1229
CPU # VCORE
Processor # VCORE
voltage regulator has
failed.
See "Getting Help" on
page 167.
Book.book Page 21 Monday, September 14, 2009 12:57 PM
Summary of Contents for PowerVault DL2000
Page 1: ...Dell PowerVault DL2000 Hardware Owner s Manual ...
Page 10: ...10 Contents Glossary 169 Index 181 ...
Page 62: ...62 Using the System Setup Program ...
Page 128: ...128 Installing System Components ...
Page 166: ...166 Jumpers and Connectors ...
Page 168: ...168 Getting Help ...
Page 180: ...180 Glossary ...
Page 188: ...188 Index ...