background image

 

                                   

INSTRUKCJA MONTAŻU/ASSEMBLY INSTRUCTIONS                              

                                  POLSKI/ENGLISH                                      

                                  Kod / code:

  AWO 229 

Nazwa/ Name: 

17/EXP/SAT/GRADE 3

 

Obudowa metalowa do: SSWiN, KD,…. 

Metal casing for: alarms, access control....

 

                                                                                                                                             

IM229

 

 

                                                                                                             

                                                                                                                 

 

Wydanie: 2 z dnia 02.11.2017  

                                                                                                   Zastępuje wydanie: 1 z dnia 15.09.2014 

    

                                                                                                                                  

                                 PL

 

1. Przeznaczenie:

 

 

Obudowy 

AWO 229

 spełniają normę 

PN-EN50131 Stopnia3. 

Zaprojektowane zostały jako elementy systemów 

SSWiN, KD, itp.  

Przeznaczone są do montażu (w zależności od modelu):  

 

płyty centrali alarmowej i opcjonalnie dodatkowych modułów  

2. Montaż:

  

 

Obudowa (+ PCB) przeznaczona jest do montażu przez wykwalifikowanego instalatora, posiadającego 

odpowiednie (wymagane i konieczne dla danego kraju) zezwolenia i uprawnienia do przyłączania (ingerencji)                                

w instalacje 230V/AC oraz instalacje niskonapięciowe. 

Obudowa (+PCB) powinna być montowana w pomieszczeniach zamkniętych, o normalnej wilgotności powietrza 

(RH=90% maks. bez kondensacji) i temperaturze z zakresu -10°C do +40°C. 

1. Destination: 

EN 

 

The 

AWO 229

 metal casings 

compliant with EN50131 GRADE3

 are designed as components (supplying) in 

intruders alarms, access control systems, security systems etc. There are intended for installation: 

 

control panel optional with supplementary modules 

 
2. Installation:  

 

 
The metal casing (+PCB) must be installed by a qualified installer, holding the relevant certificates, required and 

necessary in the particular country for connecting (interfering with) the 230V AC systems and low-voltage installations.  

The casing (+PCB) should be installed indoors, where the air humidity is normal (RH=90% max. without 

condensation) and temperature in the range of -10°C to +40°C. 

 

3. Parametry techniczne / Technical data:    

                       

PL/EN

 

 

PARAMETRY 

TECHNICZNE 

TECHNICAL 

DATA 

 

Miejsce dla akumulatora 

Space for battery 

17Ah/12V 

Zabezpieczenie antysabotażowe 

Tamper protection 

otwarcie obudowy, oderwanie 

opening casing, wall tamper 

Obciążalność wyjścia TAMPER- max 

Output current TAMPER - max 

500mA@50Vdc  

Obudowa: IP 

Casing: IP 

IP 20 

Temperatura pracy 

Operating temperature 

-10ºC÷40ºC 

Wilgotność względna  RH – max. 

Relative humidity RH –max. 

90 [%] 

Wymiary zewnętrzne obudowy 

Wymiary zewnętrzne czołówki 

External dimensions of the enclosure 

External dimensions of the front panel 

W=330, H =305, D=110, D1=15  

[-/+2mm] 

W1=325, H1=310 [+/- 2mm] 

Wykonanie 

Material description 

 

Blacha DC01, grubość: 1,0mm 

Zabezpieczenie antykorozyjne 

Kolor: RAL 9003/ 

Sheet steel DC01, Thickness: 1,0mm, 

Protection anticorrosion, 

 Color: RAL9003 

 

Zastosowanie 

Destination 

Do wewnątrz/Indoor 

Waga netto 

Net Weight  

~3.00  [kg] 

Waga brutto 

Gross Weight  

~3.30  [kg] 

 

 