About Your System
23
E1414
CPU #
Thermtrip
Specified microprocessor
is out of acceptable
temperature range and has
halted operation.
See "Troubleshooting
System Cooling Problems"
on page 140. If the problem
persists, ensure that the
microprocessor heat sinks
are properly installed. See
"Troubleshooting the
Microprocessors" on
page 150.
NOTE:
The LCD continues to
display this message until the
system’s power cord is
disconnected and
reconnected to the AC power
source, or the SEL is cleared
using either Server Assistant
or the BMC Management
Utility. See the
Dell
OpenManage Baseboard
Management Controller
User’s Guide
for information
about these utilities.
E1418
CPU #
Presence
Specified processor is
missing or bad, and the
system is in an
unsupported
configuration.
See "Troubleshooting the
Microprocessors" on
page 150.
E141C
CPU Mismatch
Processors are in a
configuration unsupported
by Dell.
Ensure that your
processors match and
conform to the type
described in the
Microprocessor Technical
Specifications outlined in
your system’s
Getting
Started Guide
.
Table 1-6.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
Book.book Page 23 Monday, September 14, 2009 12:57 PM
Summary of Contents for PowerVault DL2000
Page 1: ...Dell PowerVault DL2000 Hardware Owner s Manual ...
Page 10: ...10 Contents Glossary 169 Index 181 ...
Page 62: ...62 Using the System Setup Program ...
Page 128: ...128 Installing System Components ...
Page 166: ...166 Jumpers and Connectors ...
Page 168: ...168 Getting Help ...
Page 180: ...180 Glossary ...
Page 188: ...188 Index ...