About Your System
27
E1811
HDD ## Rbld
Abrt
The specified hard drive
has experienced a rebuild
abort.
See "Troubleshooting a
Hard Drive" on page 146.
If the problem persists, see
your RAID
documentation.
E1812
HDD ##
Removed
The specified hard drive
has been removed from
the system.
Information only.
E1913
CPU &
Firmware
Mismatch
The BMC firmware does
not support the CPU.
Update to the latest BMC
firmware. See the
BMC
User’s Guide
for more
information on setup and
use of BMC.
E1A11
PCI Rsr
Config
PCI risers are not
configured correctly; some
invalid configurations may
prevent the system from
powering on.
See "Expansion-Card Riser
Boards" on page 112.
E1A12
PCI Rsr
Missing
One or all of the PCI risers
is missing, preventing the
system from powering on.
Information only.
E1A14
SAS Cable A
SAS cable A is missing or
bad.
Reseat the cable. If
problem persists, replace
cable. See "SAS Controller
Daughter Card" on
page 85.
E1A15
SAS Cable B
SAS cable B is missing or
bad.
Reseat the cable. If
problem persists, replace
cable. See "SAS Controller
Daughter Card" on
page 85.
E2010
No Memory
No memory is installed in
the system.
Install memory. See
"Installing Memory
Modules" on page 102.
Table 1-6.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
Book.book Page 27 Monday, September 14, 2009 12:57 PM
Summary of Contents for PowerVault DL2000
Page 1: ...Dell PowerVault DL2000 Hardware Owner s Manual ...
Page 10: ...10 Contents Glossary 169 Index 181 ...
Page 62: ...62 Using the System Setup Program ...
Page 128: ...128 Installing System Components ...
Page 166: ...166 Jumpers and Connectors ...
Page 168: ...168 Getting Help ...
Page 180: ...180 Glossary ...
Page 188: ...188 Index ...