About Your System
33
Table 1-7.
System Messages
Message
Causes
Corrective Actions
Alert! Redundant
memory disabled!
Memory
configuration does
not support
redundant memory.
Installed memory modules
are not the same type and
size; faulty memory
module(s).
Ensure that all memory
modules are of the same
type and size and that they
are properly installed. If the
problem persists, see
"Troubleshooting System
Memory" on page 142.
Attempting to
update Remote
Configuration.
Please wait...
Remote Configuration
request has been detected
and is being processed.
Wait until the process is
complete.
BIOS Update
Attempt Failed!
Remote BIOS update
attempt failed.
Retry the BIOS update. If
problem persists, see
"Getting Help" on page 167.
Caution! NVRAM_CLR
jumper is
installed on
system board.
NVRAM_CLR jumper is
installed. CMOS has been
cleared.
Remove NVRAM_CLR
jumper. See Figure 6-1 for
jumper location.
CPUs with
different cache
sizes detected!
Microprocessors with
different cache sizes are
installed.
Ensure that all
microprocessors have the
same cache size and that
they are properly installed.
See "Processors" on
page 105.
Decreasing
available memory
Faulty or improperly
installed memory modules.
See "Troubleshooting
System Memory" on
page 142.
Book.book Page 33 Monday, September 14, 2009 12:57 PM
Summary of Contents for PowerVault DL2000
Page 1: ...Dell PowerVault DL2000 Hardware Owner s Manual ...
Page 10: ...10 Contents Glossary 169 Index 181 ...
Page 62: ...62 Using the System Setup Program ...
Page 128: ...128 Installing System Components ...
Page 166: ...166 Jumpers and Connectors ...
Page 168: ...168 Getting Help ...
Page 180: ...180 Glossary ...
Page 188: ...188 Index ...