Installing System Components
91
Installing the Cooling Shroud
1
Align the shroud using the center of the numbered fan bays as a guide.
2
Press the cooling shroud down into the chassis.
3
Close the system. See "Closing the System" on page 89.
4
Reconnect the system to its electrical outlet and turn the system on,
including any attached peripherals.
Hard Drives
Your system supports 3.5-inch or 2.5-inch (SAS or SATA) hard drives in
3.5-inch hot-swap hard drive carrier or cabled internal drives. Depending
on your chassis, the hard drives are installed internally or at the front of the
system (see Figure 3-1). Front-mounted hard drives are connected to a SAS
backplane through hard-drive carriers and can be configured as hot-
swappable.
NOTE:
Systems with cabled hard drives support up to four 3.5-inch SAS or
SATA hard drives.
Removing a Hard-Drive Blank
CAUTION:
To maintain proper system cooling, all empty hard-drive bays must
have drive blanks installed.
NOTE:
This section is applicable to systems with hot-swappable hard drives only.
1
Remove the front bezel. See
"Removing the Front Bezel" on page 86.
2
Grasp the front of the hard-drive blank, press the release lever on
the right side, and slide the blank out until it is free of the drive bay.
See Figure 3-7.
book.book Page 91 Friday, November 20, 2009 2:56 PM
Summary of Contents for PowerEdge R510
Page 11: ...Contents 11 7 Getting Help 199 Contacting Dell 199 Glossary 201 Index 211 ...
Page 12: ...12 Contents ...
Page 82: ...82 Using the System Setup Program and UEFI Boot Manager ...
Page 188: ...188 Troubleshooting Your System ...
Page 198: ...198 Jumpers and Connectors ...
Page 200: ...200 Getting Help ...
Page 210: ...210 Glossary ...